Commission Delegated Regulation (EU) No 626/2011 of 4 May 2011 supplementing Dire... (32011R0626)
Commission Delegated Regulation (EU) No 626/2011 of 4 May 2011 supplementing Dire... (32011R0626)
COMMISSION DELEGATED REGULATION (EU) No 626/2011
of 4 May 2011
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of air conditioners
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Responsibilities of suppliers
Article 4
Responsibilities of dealers
Article 5
Measurement methods
Article 6
Verification procedure for market surveillance purposes
Article 7
Revision
Article 8
Repeal
Article 9
Transitional provision
Article 10
Entry into force and application
ANNEX I
ANNEX II
|
Energy Efficiency Class |
SEER |
SCOP |
|
A+++ |
SEER ≥ 8,50 |
SCOP ≥ 5,10 |
|
A++ |
6,10 ≤ SEER < 8,50 |
4,60 ≤ SCOP < 5,10 |
|
A+ |
5,60 ≤ SEER < 6,10 |
4,00 ≤ SCOP < 4,60 |
|
A |
5,10 ≤ SEER < 5,60 |
3,40 ≤ SCOP < 4,00 |
|
B |
4,60 ≤ SEER < 5,10 |
3,10 ≤ SCOP < 3,40 |
|
C |
4,10 ≤ SEER < 4,60 |
2,80 ≤ SCOP < 3,10 |
|
D |
3,60 ≤ SEER < 4,10 |
2,50 ≤ SCOP < 2,80 |
|
E |
3,10 ≤ SEER < 3,60 |
2,20 ≤ SCOP < 2,50 |
|
F |
2,60 ≤ SEER < 3,10 |
1,90 ≤ SCOP < 2,20 |
|
G |
SEER < 2,60 |
SCOP < 1,90 |
|
Energy Efficiency Class |
Double ducts |
Single ducts |
||
|
|
EERrated |
COPrated |
EERrated |
COPrated |
|
A+++ |
≥ 4,10 |
≥ 4,60 |
≥ 4,10 |
≥ 3,60 |
|
A++ |
3,60 ≤ EER < 4,10 |
4,10 ≤ COP < 4,60 |
3,60 ≤ EER < 4,10 |
3,10 ≤ COP < 3,60 |
|
A+ |
3,10 ≤ EER < 3,60 |
3,60 ≤ COP < 4,10 |
3,10 ≤ EER < 3,60 |
2,60 ≤ COP < 3,10 |
|
A |
2,60 ≤ EER < 3,10 |
3,10 ≤ COP < 3,60 |
2,60 ≤ EER < 3,10 |
2,30 ≤ COP < 2,60 |
|
B |
2,40 ≤ EER < 2,60 |
2,60 ≤ COP < 3,10 |
2,40 ≤ EER < 2,60 |
2,00 ≤ COP < 2,30 |
|
C |
2,10 ≤ EER < 2,40 |
2,40 ≤ COP < 2,60 |
2,10 ≤ EER < 2,40 |
1,80 ≤ COP < 2,00 |
|
D |
1,80 ≤ EER < 2,10 |
2,00 ≤ COP < 2,40 |
1,80 ≤ EER < 2,10 |
1,60 ≤ COP < 1,80 |
|
E |
1,60 ≤ EER < 1,80 |
1,80 ≤ COP < 2,00 |
1,60 ≤ EER < 1,80 |
1,40 ≤ COP < 1,60 |
|
F |
1,40 ≤ EER < 1,60 |
1,60 ≤ COP < 1,80 |
1,40 ≤ EER < 1,60 |
1,20 ≤ COP < 1,40 |
|
G |
< 1,40 |
< 1,60 |
< 1,40 |
< 1,20 |
ANNEX III
1. LABEL OF AIR CONDITIONERS, EXCEPT SINGLE DUCT AND DOUBLE DUCT AIR CONDITIONERS
1.1.
1.2.
1.3.
1.4.
1.5.
|
Value: |
Calibri bold 15 pt, 100 % black; |
|
Calibri regular 12 pt, 100 % black. |
2. LABEL OF AIR CONDITIONERS, EXCEPT SINGLE DUCT AND DOUBLE DUCT AIR CONDITIONERS
2.1.
2.2.
2.3.
2.4.
2.5.
3. LABEL OF AIR CONDITIONERS, EXCEPT SINGLE DUCT AND DOUBLE DUCT AIR CONDITIONERS
3.1.
3.2.
3.3.
3.4.
3.5.
4. LABEL OF DOUBLE DUCT AIR CONDITIONERS
4.1.
4.2.
|
Text: |
Calibri bold 18 pt, capitals, white; |
|
Calibri bold 7 pt, white. |
|
Text: |
Calibri bold 18 pt, capitals, white. |
|
Calibri bold 7 pt, white. |
4.3.
4.4.
|
Text: |
Calibri bold 18 pt, capitals, white; |
|
Calibri bold 7 pt, white. |
|
Text: |
Calibri bold 30 pt, capitals, white; |
|
Calibri bold 14 pt, white. |
4.5.
4.6.
|
Text: |
Calibri Bold 18 pt, capitals, white; |
|
Calibri bold 7 pt, white. |
|
Text: |
Calibri bold 30 pt, capitals, white; |
|
Calibri bold 14 pt, white. |
5. LABEL OF SINGLE DUCT AIR CONDITIONERS
5.1.
5.2.
|
Text: |
Calibri bold 18 pt, capitals, white; |
|
Calibri bold 7 pt, white. |
5.3.
5.4.
|
Text: |
Calibri bold 18 pt, capitals, white; |
|
Calibri bold 7 pt, white. |
|
Text: |
Calibri bold 30 pt, capitals, white; |
|
Calibri bold 14 pt, capitals, white. |
5.5.
5.6.
|
Text: |
Calibri bold 18 pt, capitals, white; |
|
Calibri bold 7 pt, white. |
|
Text: |
Calibri bold 30 pt, capitals, white; |
|
Calibri bold 14 pt, capitals, white. |
ANNEX IV
ANNEX V
ANNEX VI
ANNEX VII
|
COOLING SEASON |
|
HEATING SEASON |
||||||
|
|
|
|
|
|
|
Average |
Warmer |
Colder |
|
j # |
Tj °C |
hj h |
|
j # |
Tj °C |
hjA h |
hj W h |
hjC h |
|
|
db |
|
|
|
db |
|
|
|
|
1 |
17 |
205 |
|
1 to 8 |
– 30 to – 23 |
0 |
0 |
0 |
|
2 |
18 |
227 |
|
9 |
–22 |
0 |
0 |
1 |
|
3 |
19 |
225 |
|
10 |
–21 |
0 |
0 |
6 |
|
4 |
20 |
225 |
|
11 |
–20 |
0 |
0 |
13 |
|
5 |
21 |
216 |
|
12 |
–19 |
0 |
0 |
17 |
|
6 |
22 |
215 |
|
13 |
–18 |
0 |
0 |
19 |
|
7 |
23 |
218 |
|
14 |
–17 |
0 |
0 |
26 |
|
8 |
24 |
197 |
|
15 |
–16 |
0 |
0 |
39 |
|
9 |
25 |
178 |
|
16 |
–15 |
0 |
0 |
41 |
|
10 |
26 |
158 |
|
17 |
–14 |
0 |
0 |
35 |
|
11 |
27 |
137 |
|
18 |
–13 |
0 |
0 |
52 |
|
12 |
28 |
109 |
|
19 |
–12 |
0 |
0 |
37 |
|
13 |
29 |
88 |
|
20 |
–11 |
0 |
0 |
41 |
|
14 |
30 |
63 |
|
21 |
–10 |
1 |
0 |
43 |
|
15 |
31 |
39 |
|
22 |
–9 |
25 |
0 |
54 |
|
16 |
32 |
31 |
|
23 |
–8 |
23 |
0 |
90 |
|
17 |
33 |
24 |
|
24 |
–7 |
24 |
0 |
125 |
|
18 |
34 |
17 |
|
25 |
–6 |
27 |
0 |
169 |
|
19 |
35 |
13 |
|
26 |
–5 |
68 |
0 |
195 |
|
20 |
36 |
9 |
|
27 |
–4 |
91 |
0 |
278 |
|
21 |
37 |
4 |
|
28 |
–3 |
89 |
0 |
306 |
|
22 |
38 |
3 |
|
29 |
–2 |
165 |
0 |
454 |
|
23 |
39 |
1 |
|
30 |
–1 |
173 |
0 |
385 |
|
24 |
40 |
0 |
|
31 |
0 |
240 |
0 |
490 |
|
|
|
|
|
32 |
1 |
280 |
0 |
533 |
|
|
|
|
|
33 |
2 |
320 |
3 |
380 |
|
|
|
|
|
34 |
3 |
357 |
22 |
228 |
|
|
|
|
|
35 |
4 |
356 |
63 |
261 |
|
|
|
|
|
36 |
5 |
303 |
63 |
279 |
|
|
|
|
|
37 |
6 |
330 |
175 |
229 |
|
|
|
|
|
38 |
7 |
326 |
162 |
269 |
|
|
|
|
|
39 |
8 |
348 |
259 |
233 |
|
|
|
|
|
40 |
9 |
335 |
360 |
230 |
|
|
|
|
|
41 |
10 |
315 |
428 |
243 |
|
|
|
|
|
42 |
11 |
215 |
430 |
191 |
|
|
|
|
|
43 |
12 |
169 |
503 |
146 |
|
|
|
|
|
44 |
13 |
151 |
444 |
150 |
|
|
|
|
|
45 |
14 |
105 |
384 |
97 |
|
|
|
|
|
46 |
15 |
74 |
294 |
61 |
|
Total |
|
2 602 |
|
|
|
4 910 |
3 590 |
6 446 |
|
Function / season |
Indoor air temperature (°C) |
Outdoor air temperature (°C) |
Bivalent temperature (°C) |
Operating limit temperature (°C) |
|
|
Tin |
Tdesignc/Tdesignh |
Tbiv |
Tol |
|
cooling |
27 (19) |
Tdesignc = 35 (24) |
n.a. |
n.a. |
|
heating / Average |
20 (15) |
Tdesignh = – 10 (– 11) |
max. 2 |
max. – 7 |
|
heating / Warmer |
Tdesignh = 2 (1) |
max. 7 |
max. 2 |
|
|
heating / Colder |
Tdesignh = – 22 (– 23) |
max. – 7 |
max. – 15 |
|
Type of appliance / functionality (if applicable) |
Unit |
Heating season |
On mode |
Thermostat-off mode |
Standby mode |
Off mode |
Crankcase heater mode |
|
|
|
|
|
cooling: HCE heating: HHE |
HTO |
HSB |
HOFF |
HCK |
|
|
Air conditioners, except double ducts and single duct |
||||||||
|
Cooling mode, if appliance offers cooling only |
h/annum |
|
350 |
221 |
2 142 |
5 088 |
7 760 |
|
|
Cooling and heating modes, if appliance offers both modes |
Cooling mode |
h/annum |
|
350 |
221 |
2 142 |
0 |
2 672 |
|
Heating mode |
h/annum |
Average |
1 400 |
179 |
0 |
0 |
179 |
|
|
Warmer |
1 400 |
755 |
0 |
0 |
755 |
|||
|
Colder |
2 100 |
131 |
0 |
0 |
131 |
|||
|
Heating mode, if appliance offers heating only |
h/annum |
Average |
1 400 |
179 |
0 |
3 672 |
3 851 |
|
|
Warmer |
1 400 |
755 |
0 |
4 345 |
4 476 |
|||
|
Colder |
2 100 |
131 |
0 |
2 189 |
2 944 |
|||
|
Double duct air conditioner |
|
|
cooling: HCE heating: HHE |
HTO |
HSB |
HOFF |
HCK |
|
|
Cooling mode, if appliance offers cooling only |
h/60 min |
|
1 |
n/a |
n/a |
n/a |
n/a |
|
|
Cooling and heating modes, if appliance offers both modes |
Cooling mode |
h/60 min |
|
1 |
n/a |
n/a |
n/a |
n/a |
|
Heating mode |
h/60 min |
|
1 |
n/a |
n/a |
n/a |
n/a |
|
|
Heating mode, if appliance offers heating only |
h/60 min |
|
1 |
n/a |
n/a |
n/a |
n/a |
|
|
Single duct air conditioner |
|
|
cooling: HCE heating: HHE |
|
|
|
|
|
|
Cooling mode |
h/60 min |
|
1 |
n/a |
n/a |
n/a |
n/a |
|
|
Heating mode |
h/60 min |
|
1 |
n/a |
n/a |
n/a |
n/a |
|