COMMISSION DECISION
of 1 March 2013
establishing the guidelines for Member States on calculating renewable energy from heat pumps from different heat pump technologies pursuant to Article 5 of Directive 2009/28/EC of the European Parliament and of the Council
(notified under document C(2013) 1082)
(Text with EEA relevance)
(2013/114/EU)
Article 1
Article 2
Article 3
ANNEX
Guidelines for Member States on calculating renewable energy from heat pumps from different heat pump technologies pursuant to Article 5 of Directive 2009/28/EC
1. INTRODUCTION
2. DEFINITIONS
3. ESTIMATING SPF AND Q
USABLE
3.1.
Methodology Principles
3.2.
Outline of methodology
3.3.
Minimum performance of heat pumps to be considered as renewable energy under the Directive
3.4.
System boundaries for measuring energy from heat pumps
Figure 1
System boundaries for measurement of SPF and Q
usable
3.5.
Climate conditions
Figure 2
Climate condition areas
3.6.
Default values for SPF and Q
usable
for heat pumps
|
Climate conditions |
||||||
Warmer climate |
Average climate |
Colder climate |
|||||
Heat Pump Energy source: |
Energy source and distribution medium |
HHP |
SPF (SCOPnet) |
HHP |
SPF (SCOPnet) |
HHP |
SPF (SCOPnet) |
Aerothermal energy |
Air-Air |
1 200 |
2,7 |
1 770 |
2,6 |
1 970 |
2,5 |
Air-Water |
1 170 |
2,7 |
1 640 |
2,6 |
1 710 |
2,5 |
|
Air-Air (reversible) |
480 |
2,7 |
710 |
2,6 |
1 970 |
2,5 |
|
Air-Water (reversible) |
470 |
2,7 |
660 |
2,6 |
1 710 |
2,5 |
|
Exhaust Air-Air |
760 |
2,7 |
660 |
2,6 |
600 |
2,5 |
|
Exhaust Air-Water |
760 |
2,7 |
660 |
2,6 |
600 |
2,5 |
|
Geothermal energy |
Ground-Air |
1 340 |
3,2 |
2 070 |
3,2 |
2 470 |
3,2 |
Ground-Water |
1 340 |
3,5 |
2 070 |
3,5 |
2 470 |
3,5 |
|
Hydrothermal heat |
Water-Air |
1 340 |
3,2 |
2 070 |
3,2 |
2 470 |
3,2 |
Water-Water |
1 340 |
3,5 |
2 070 |
3,5 |
2 470 |
3,5 |
|
Climate conditions |
||||||
Warmer climate |
Average climate |
Colder climate |
|||||
Heat Pump Energy source: |
Energy source and distribution medium |
HHP |
SPF (SPERnet) |
HHP |
SPF (SPERnet) |
HHP |
SPF (SPERnet) |
Aerothermal energy |
Air-Air |
1 200 |
1,2 |
1 770 |
1,2 |
1 970 |
1,15 |
Air-Water |
1 170 |
1,2 |
1 640 |
1,2 |
1 710 |
1,15 |
|
Air-Air (reversible) |
480 |
1,2 |
710 |
1,2 |
1 970 |
1,15 |
|
Air-Water (reversible) |
470 |
1,2 |
660 |
1,2 |
1 710 |
1,15 |
|
Exhaust Air-Air |
760 |
1,2 |
660 |
1,2 |
600 |
1,15 |
|
Exhaust Air-Water |
760 |
1,2 |
660 |
1,2 |
600 |
1,15 |
|
Geothermal energy |
Ground-Air |
1 340 |
1,4 |
2 070 |
1,4 |
2 470 |
1,4 |
Ground-Water |
1 340 |
1,6 |
2 070 |
1,6 |
2 470 |
1,6 |
|
Hydrothermal heat |
Water-Air |
1 340 |
1,4 |
2 070 |
1,4 |
2 470 |
1,4 |
Water-Water |
1 340 |
1,6 |
2 070 |
1,6 |
2 470 |
1,6 |
3.7.
Remarks related to non-electrically driven heat pumps
3.8.
Remarks related to heat pumps using exhaust air as energy source
3.9.
Remarks to air sourced heat pumps
3.10.
Remarks related to reversible heat pumps
3.11.
Renewable energy contribution from hybrid heat pump systems
3.12.
Guidance on the development of more accurate methodologies
4. CALCULATION EXAMPLE
|
|
|
|
Air to air (reversible) |
Water to water |
Exhaust Air to water |
Calculation |
Description |
Variable |
Unit |
|
|
|
|
Capacity of heat pumps installed |
Prated |
GW |
255 |
74 |
215 |
|
of which the SPF is above the minimum threshold |
Prated |
GW |
150 |
70 |
120 |
|
Equivalent full load hours of operation |
HHP |
h |
852(11) |
2 010 |
660 |
[Bild bitte in Originalquelle ansehen] |
Estimated total usable heat delivered by heat pumps |
Qusable |
GWh |
127 800 |
144 900 |
79 200 |
|
the estimated average seasonal performance factor |
SPF |
|
2,6 |
3,5 |
2,6 |
[Bild bitte in Originalquelle ansehen] |
Amount of renewable energy supplied per heat pump technology |
ERES |
GWh |
78 646 |
103 500 |
48 738 |
|
Total amount of renewable energy supplied by heat pumps |
ERES |
GWh |
|
230 885 |
|