COMMISSION DELEGATED REGULATION (EU) No 811/2013
of 18 February 2013
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Responsibilities of suppliers and timetable
Article 4
Responsibilities of dealers
Article 5
Measurement and calculation methods
Article 6
Verification procedure for market surveillance purposes
Article 7
Review
Article 8
Entry into force and application
ANNEX I
Definitions applicable for Annexes II to VIII
ANNEX II
Energy efficiency classes
1. SEASONAL SPACE HEATING ENERGY EFFICIENCY CLASSES
Seasonal space heating energy efficiency class |
Seasonal space heating energy efficiency ηs in % |
A+++ |
ηs ≥ 150 |
A++ |
125 ≤ ηs < 150 |
A+ |
98 ≤ ηs < 125 |
A |
90 ≤ ηs < 98 |
B |
82 ≤ ηs < 90 |
C |
75 ≤ ηs < 82 |
D |
36 ≤ ηs < 75 |
E |
34 ≤ ηs < 36 |
F |
30 ≤ ηs < 34 |
G |
ηs < 30 |
Seasonal space heating energy efficiency class |
Seasonal space heating energy efficiency ηs in % |
A+++ |
ηs ≥ 175 |
A++ |
150 ≤ ηs < 175 |
A+ |
123 ≤ ηs < 150 |
A |
115 ≤ ηs < 123 |
B |
107 ≤ ηs < 115 |
C |
100 ≤ ηs < 107 |
D |
61 ≤ ηs < 100 |
E |
59 ≤ ηs < 61 |
F |
55 ≤ ηs < 59 |
G |
ηs < 55 |
2. WATER HEATING ENERGY EFFICIENCY CLASSES
|
3XS |
XXS |
XS |
S |
M |
L |
XL |
XXL |
A+++ |
ηwh ≥ 62 |
ηwh ≥ 62 |
ηwh ≥ 69 |
ηwh ≥ 90 |
ηwh ≥ 163 |
ηwh ≥ 188 |
ηwh ≥ 200 |
ηwh ≥ 213 |
A++ |
53 ≤ ηwh < 62 |
53 ≤ ηwh < 62 |
61 ≤ ηwh < 69 |
72 ≤ ηwh < 90 |
130 ≤ ηwh < 163 |
150 ≤ ηwh < 188 |
160 ≤ ηwh < 200 |
170 ≤ ηwh < 213 |
A+ |
44 ≤ ηwh < 53 |
44 ≤ ηwh < 53 |
53 ≤ ηwh < 61 |
55 ≤ ηwh < 72 |
100 ≤ ηwh < 130 |
115 ≤ ηwh < 150 |
123 ≤ ηwh < 160 |
131 ≤ ηwh < 170 |
A |
35 ≤ ηwh < 44 |
35 ≤ ηwh < 44 |
38 ≤ ηwh < 53 |
38 ≤ ηwh < 55 |
65 ≤ ηwh < 100 |
75 ≤ ηwh < 115 |
80 ≤ ηwh < 123 |
85 ≤ ηwh < 131 |
B |
32 ≤ ηwh < 35 |
32 ≤ ηwh < 35 |
35 ≤ ηwh < 38 |
35 ≤ ηwh < 38 |
39 ≤ ηwh < 65 |
50 ≤ ηwh < 75 |
55 ≤ ηwh < 80 |
60 ≤ ηwh < 85 |
C |
29 ≤ ηwh < 32 |
29 ≤ ηwh < 32 |
32 ≤ ηwh < 35 |
32 ≤ ηwh < 35 |
36 ≤ ηwh < 39 |
37 ≤ ηwh < 50 |
38 ≤ ηwh < 55 |
40 ≤ ηwh < 60 |
D |
26 ≤ ηwh < 29 |
26 ≤ ηwh < 29 |
29 ≤ ηwh < 32 |
29 ≤ ηwh < 32 |
33 ≤ ηwh < 36 |
34 ≤ ηwh < 37 |
35 ≤ ηwh < 38 |
36 ≤ ηwh < 40 |
E |
22 ≤ ηwh < 26 |
23 ≤ ηwh < 26 |
26 ≤ ηwh < 29 |
26 ≤ ηwh < 29 |
30 ≤ ηwh < 33 |
30 ≤ ηwh < 34 |
30 ≤ ηwh < 35 |
32 ≤ ηwh < 36 |
F |
19 ≤ ηwh < 22 |
20 ≤ ηwh < 23 |
23 ≤ ηwh < 26 |
23 ≤ ηwh < 26 |
27 ≤ ηwh < 30 |
27 ≤ ηwh < 30 |
27 ≤ ηwh < 30 |
28 ≤ ηwh < 32 |
G |
ηwh < 19 |
ηwh < 20 |
ηwh < 23 |
ηwh < 23 |
ηwh < 27 |
ηwh < 27 |
ηwh < 27 |
ηwh < 28 |
3. ENERGY EFFICIENCY CLASSES OF SOLAR HOT WATER STORAGE TANKS, IF (PART OF) A SOLAR DEVICE
Energy efficiency class |
Standing loss S in Watts, with storage volume V in litres |
A+ |
[Bild bitte in Originalquelle ansehen] |
A |
[Bild bitte in Originalquelle ansehen] |
B |
[Bild bitte in Originalquelle ansehen] |
C |
[Bild bitte in Originalquelle ansehen] |
D |
[Bild bitte in Originalquelle ansehen] |
E |
[Bild bitte in Originalquelle ansehen] |
F |
[Bild bitte in Originalquelle ansehen] |
G |
[Bild bitte in Originalquelle ansehen] |
ANNEX III
The labels
1. SPACE HEATERS
1.1.
Label 1
1.1.1.
Boiler space heaters in seasonal space heating energy efficiency classes A
++
to G
1.1.2.
Cogeneration space heaters in seasonal space heating energy efficiency classes A
++
to G
1.1.3.
Heat pump space heaters, except low-temperature heat pumps, in seasonal space heating energy efficiency classes A
++
to G
1.1.4.
Low-temperature heat pumps in seasonal space heating energy efficiency classes A
++
to G
1.2.
Label 2
1.2.1.
Boiler space heaters in seasonal space heating energy efficiency classes A
+++
to D
1.2.2.
Cogeneration space heaters in seasonal space heating energy efficiency classes A
+++
to D
1.2.3.
Heat pump space heaters, except low-temperature heat pumps, in seasonal space heating energy efficiency classes A
+++
to D
1.2.4.
Low-temperature heat pumps in seasonal space heating energy efficiency classes A
+++
to D
2. COMBINATION HEATERS
2.1.
Label 1
2.1.1
Boiler combination heaters in seasonal space heating energy efficiency classes A
++
to G and in water heating energy efficiency classes A to G
2.1.2.
Heat pump combination heaters in seasonal space heating energy efficiency classes A
++
to G and in water heating energy efficiency classes A to G
2.2.
Label 2
2.2.1.
Boiler combination heaters in seasonal space heating energy efficiency classes A
+++
to D and in water heating energy efficiency classes A
+
to F
2.2.2.
Heat pump combination heaters in seasonal space heating energy efficiency classes A
+++
to D and in water heating energy efficiency classes A
+
to F
3. PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
Label for packages of space heater, temperature control and solar device in seasonal space heating energy efficiency classes A
+++
to G
4. PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
Label for packages of combination heater, temperature control and solar device in seasonal space heating and water heating energy efficiency classes A
+++
to G
11. The design of the label for packages of space heater, temperature control and solar device shall be the following:
12. The design of the label for packages of combination heater, temperature control and solar device shall be the following:
ANNEX IV
Product fiche
1. SPACE HEATERS
2. COMBINATION HEATERS
3. TEMPERATURE CONTROLS
4. SOLAR DEVICES
5. PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
6. PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
[Bild bitte in Originalquelle ansehen] (2) |
II, package without hot water storage tank |
II, package with hot water storage tank |
0 |
0 |
0 |
0,1 |
0,30 |
0,37 |
0,2 |
0,55 |
0,70 |
0,3 |
0,75 |
0,85 |
0,4 |
0,85 |
0,94 |
0,5 |
0,95 |
0,98 |
0,6 |
0,98 |
1,00 |
≥ 0,7 |
1,00 |
1,00 |
[Bild bitte in Originalquelle ansehen] (4) |
II, package without hot water storage tank |
II, package with hot water storage tank |
0 |
1,00 |
1,00 |
0,1 |
0,70 |
0,63 |
0,2 |
0,45 |
0,30 |
0,3 |
0,25 |
0,15 |
0,4 |
0,15 |
0,06 |
0,5 |
0,05 |
0,02 |
0,6 |
0,02 |
0 |
≥ 0,7 |
0 |
0 |
Figure 1
For preferential boiler space heaters and preferential boiler combination heaters, element of the fiche for a package of space heater, temperature control and solar device and a package of combination heater, temperature control and solar device, respectively, indicating the seasonal space heating energy efficiency of the package offered
Figure 2
For preferential cogeneration space heaters, element of the fiche for a package of space heater, temperature control and solar device indicating the seasonal space heating energy efficiency of the package offered
Figure 3
For preferential heat pump space heaters and preferential heat pump combination heaters, element of the fiche for a package of space heater, temperature control and solar device and a package of combination heater, temperature control and solar device, respectively, indicating the seasonal space heating energy efficiency of the package offered
Figure 4
For preferential low-temperature heat pumps, element of the fiche for a package of space heater, temperature control and solar device indicating the seasonal space heating energy efficiency of the package offered
Figure 5
For preferential boiler combination heaters and preferential heat pump combination heaters, element of the fiche for a package of combination heater, temperature control and solar device indicating the water heating energy efficiency of the package offered
ANNEX V
Technical documentation
1. SPACE HEATERS
2. COMBINATION HEATERS
Model(s): [information identifying the model(s) to which the information relates] |
||||||||
Condensing boiler: [yes/no] |
||||||||
Low-temperature(2) boiler: [yes/no] |
||||||||
B11 boiler: [yes/no] |
||||||||
Cogeneration space heater: [yes/no] |
If yes, equipped with a supplementary heater: [yes/no] |
|||||||
Combination heater: [yes/no] |
||||||||
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
Rated heat output |
Prated |
x |
kW |
Seasonal space heating energy efficiency |
ηs |
x |
% |
|
For boiler space heaters and boiler combination heaters: Useful heat output |
For boiler space heaters and boiler combination heaters: Useful efficiency |
|||||||
At rated heat output and high-temperature regime(1) |
P4 |
x,x |
kW |
At rated heat output and high-temperature regime(1) |
η4 |
x,x |
% |
|
At 30 % of rated heat output and low-temperature regime(2) |
P1 |
x,x |
kW |
At 30 % of rated heat output and low-temperature regime(2) |
η1 |
x,x |
% |
|
For cogeneration space heaters: Useful heat output |
For cogeneration space heaters: Useful efficiency |
|||||||
At rated heat output of cogeneration space heater with supplementary heater disabled |
PCHP100+Sup0 |
x,x |
kW |
At rated heat output of cogeneration space heater with supplementary heater disabled |
ηCHP100+Sup0 |
x,x |
% |
|
At rated heat output of cogeneration space heater with supplementary heater enabled |
PCHP100+Sup100 |
x,x |
kW |
At rated heat output of cogeneration space heater with supplementary heater enabled |
ηCHP100+Sup100 |
x,x |
% |
|
For cogeneration space heaters: Electrical efficiency |
Supplementary heater |
|||||||
At rated heat output of cogeneration space heater with supplementary heater disabled |
ηel,CHP100+Sup0 |
x,x |
% |
Rated heat output |
Psup |
x,x |
kW |
|
At rated heat output of cogeneration space heater with supplementary heater enabled |
ηel,CHP100+Sup100 |
x,x |
% |
Type of energy input |
|
|||
Auxiliary electricity consumption |
Other items |
|||||||
At full load |
elmax |
x,x |
kW |
Standby heat loss |
Pstby |
x,x |
kW |
|
At part load |
elmin |
x,x |
kW |
Ignition burner power consumption |
Pign |
x,x |
kW |
|
In standby mode |
PSB |
x,xxx |
kW |
Annual energy consumption |
QHE |
x |
kWh or GJ |
|
Sound power level, indoors |
LWA |
x |
dB |
|||||
For combination heaters: |
||||||||
Declared load profile |
|
|
Water heating energy efficiency |
ηwh |
x |
% |
||
Daily electricity consumption |
Qelec |
x,xxx |
kWh |
Daily fuel consumption |
Qfuel |
x,xxx |
kWh |
|
Annual electricity consumption |
AEC |
x |
kWh |
Annual fuel consumption |
AFC |
x |
GJ |
|
Contact details |
Name and address of the supplier. |
Model(s): [information identifying the model(s) to which the information relates] |
||||||||
Air-to-water heat pump: [yes/no] |
||||||||
Water-to-water heat pump: [yes/no] |
||||||||
Brine-to-water heat pump: [yes/no] |
||||||||
Low-temperature heat pump: [yes/no] |
||||||||
Equipped with a supplementary heater: [yes/no] |
||||||||
Heat pump combination heater: [yes/no] |
||||||||
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters shall be declared for low-temperature application. |
||||||||
Parameters shall be declared for average, colder and warmer climate conditions. |
||||||||
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
Rated heat output (3) |
Prated |
x |
kW |
Seasonal space heating energy efficiency |
ηs |
x |
% |
|
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj |
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj |
|||||||
Tj = – 7 °C |
Pdh |
x,x |
kW |
Tj = – 7 °C |
COPd or PERd |
x,xx or x,x |
– or % |
|
Tj = + 2 °C |
Pdh |
x,x |
kW |
Tj = + 2 °C |
COPd or PERd |
x,xx or x,x |
– or % |
|
Tj = + 7 °C |
Pdh |
x,x |
kW |
Tj = + 7 °C |
COPd or PERd |
x,xx or x,x |
– or % |
|
Tj = + 12 °C |
Pdh |
x,x |
kW |
Tj = + 12 °C |
COPd or PERd |
x,xx or x,x |
– or % |
|
Tj = bivalent temperature |
Pdh |
x,x |
kW |
Tj = bivalent temperature |
COPd or PERd |
x,xx or x,x |
– or % |
|
Tj = operation limit temperature |
Pdh |
x,x |
kW |
Tj = operation limit temperature |
COPd or PERd |
x,xx or x,x |
– or % |
|
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C) |
Pdh |
x,x |
kW |
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C) |
COPd or PERd |
x,xx or x,x |
– or % |
|
Bivalent temperature |
Tbiv |
x |
°C |
For air-to-water heat pumps: Operation limit temperature |
TOL |
x |
°C |
|
Cycling interval capacity for heating |
Pcych |
x,x |
kW |
Cycling interval efficiency |
COPcyc or PERcyc |
x,xx or x,x |
– or % |
|
Degradation co-efficient(4) |
Cdh |
x,x |
— |
Heating water operating limit temperature |
WTOL |
x |
°C |
|
Power consumption in modes other than active mode |
Supplementary heater |
|||||||
Off mode |
POFF |
x,xxx |
kW |
Rated heat output(4) |
Psup |
x,x |
kW |
|
Thermostat-off mode |
PTO |
x,xxx |
kW |
|
|
|||
Standby mode |
PSB |
x,xxx |
kW |
Type of energy input |
||||
Crankcase heater mode |
PCK |
x,xxx |
kW |
|
||||
Other items |
|
|||||||
Capacity control |
fixed/variable |
For air-to-water heat pumps: Rated air flow rate, outdoors |
— |
x |
m3/h |
|||
Sound power level, indoors/outdoors |
LWA |
x / x |
dB |
For water- or brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger |
— |
x |
m3/h |
|
Annual energy consumption |
QHE |
x |
kWh or GJ |
|||||
For heat pump combination heater: |
||||||||
Declared load profile |
x |
|
Water heating energy efficiency |
ηwh |
x |
% |
||
Daily electricity consumption |
Qelec |
x,xxx |
kWh |
Daily fuel consumption |
Qfuel |
x,xxx |
kWh |
|
Annual electricity consumption |
AEC |
x |
kWh |
Annual fuel consumption |
AFC |
x |
GJ |
|
Contact details |
Name and address of the supplier. |
3. TEMPERATURE CONTROLS
4. SOLAR DEVICES
5. PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
6. PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
ANNEX VI
Information to be provided in cases where end-users cannot be expected to see the product displayed
1. SPACE HEATERS
2. COMBINATION HEATERS
3. PACKAGES OF SPACE HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
4. PACKAGES OF COMBINATION HEATER, TEMPERATURE CONTROL AND SOLAR DEVICE
ANNEX VII
Measurements and calculations
2.
General conditions for measurements and calculations
3.
Seasonal space heating energy efficiency and consumption of boiler space heaters, boiler combination heaters and cogeneration space heaters
4.
Seasonal space heating energy efficiency and consumption of heat pump space heaters and heat pump combination heaters
5.
Water heating energy efficiency of combination heaters
6.
Conditions for measurements and calculations of solar devices
Heat source |
Outdoor heat exchanger |
Indoor heat exchanger |
||||
Climate condition |
Inlet dry bulb (wet bulb) temperature |
Heat pump space heaters and heat pump combination heaters, except low-temperature heat pumps |
Low-temperature heat pumps |
|||
Inlet temperature |
Outlet temperature |
Inlet temperature |
Outlet temperature |
|||
Outdoor air |
Average |
+ 7 °C (+ 6 °C) |
+47 °C |
+55 °C |
+30 °C |
+35 °C |
|
Colder |
+ 2 °C (+ 1 °C) |
||||
|
Warmer |
+ 14 °C (+ 13 °C) |
||||
Exhaust air |
All |
+ 20 °C (+ 12 °C) |
||||
|
|
Inlet / outlet temperature |
||||
Water |
All |
+ 10 °C / + 7 °C |
||||
Brine |
All |
0 °C/– 3 °C |
Climate condition |
Reference design temperature |
Bivalent temperature |
Operation limit temperature |
Tdesignh |
Tbiv |
TOL |
|
Average |
– 10 (– 11) °C |
maximum + 2 °C |
maximum – 7 °C |
Colder |
– 22 (– 23) °C |
maximum – 7 °C |
maximum – 15 °C |
Warmer |
+ 2 (+ 1) °C |
maximum + 7 °C |
maximum + 2 °C |
Declared load profile |
XXS |
XS |
S |
M |
L |
XL |
XXL |
Maximum ventilation exhaust air available |
109 |
128 |
128 |
159 |
190 |
870 |
1 021 |
binj |
Tj [°C] |
Average climate conditions |
Colder climate conditions |
Warmer climate conditions |
Hj [h/annum] |
Hj [h/annum] |
Hj [h/annum] |
||
1 to 8 |
–30 to –23 |
0 |
0 |
0 |
9 |
–22 |
0 |
1 |
0 |
10 |
–21 |
0 |
6 |
0 |
11 |
–20 |
0 |
13 |
0 |
12 |
–19 |
0 |
17 |
0 |
13 |
–18 |
0 |
19 |
0 |
14 |
–17 |
0 |
26 |
0 |
15 |
–16 |
0 |
39 |
0 |
16 |
–15 |
0 |
41 |
0 |
17 |
–14 |
0 |
35 |
0 |
18 |
–13 |
0 |
52 |
0 |
19 |
–12 |
0 |
37 |
0 |
20 |
–11 |
0 |
41 |
0 |
21 |
–10 |
1 |
43 |
0 |
22 |
–9 |
25 |
54 |
0 |
23 |
–8 |
23 |
90 |
0 |
24 |
–7 |
24 |
125 |
0 |
25 |
–6 |
27 |
169 |
0 |
26 |
–5 |
68 |
195 |
0 |
27 |
–4 |
91 |
278 |
0 |
28 |
–3 |
89 |
306 |
0 |
29 |
–2 |
165 |
454 |
0 |
30 |
–1 |
173 |
385 |
0 |
31 |
0 |
240 |
490 |
0 |
32 |
1 |
280 |
533 |
0 |
33 |
2 |
320 |
380 |
3 |
34 |
3 |
357 |
228 |
22 |
35 |
4 |
356 |
261 |
63 |
36 |
5 |
303 |
279 |
63 |
37 |
6 |
330 |
229 |
175 |
38 |
7 |
326 |
269 |
162 |
39 |
8 |
348 |
233 |
259 |
40 |
9 |
335 |
230 |
360 |
41 |
10 |
315 |
243 |
428 |
42 |
11 |
215 |
191 |
430 |
43 |
12 |
169 |
146 |
503 |
44 |
13 |
151 |
150 |
444 |
45 |
14 |
105 |
97 |
384 |
46 |
15 |
74 |
61 |
294 |
Total hours: |
4 910 |
6 446 |
3 590 |
|
January |
February |
March |
April |
May |
June |
July |
August |
September |
October |
November |
December |
Average climate conditions |
+2,8 |
+2,6 |
+7,4 |
+12,2 |
+16,3 |
+19,8 |
+21,0 |
+22,0 |
+17,0 |
+11,9 |
+5,6 |
+3,2 |
|
January |
February |
March |
April |
May |
June |
July |
August |
September |
October |
November |
December |
Average climate conditions |
70 |
104 |
149 |
192 |
221 |
222 |
232 |
217 |
176 |
129 |
80 |
56 |
h |
3XS |
XXS |
XS |
S |
|||||||||
Qtap |
f |
Tm |
Qtap |
f |
Tm |
Qtap |
f |
Tm |
Qtap |
f |
Tm |
Tp |
|
kWh |
l/min |
°C |
kWh |
l/min |
°C |
kWh |
l/min |
°C |
kWh |
l/min |
°C |
°C |
|
07:00 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
25 |
|
07:05 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
07:15 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
07:26 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
07:30 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
0,525 |
3 |
35 |
0,105 |
3 |
25 |
|
07:45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
08:01 |
|
|
|
|
|
|
|
|
|
|
|
|
|
08:05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
08:15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
08:25 |
|
|
|
|
|
|
|
|
|
|
|
|
|
08:30 |
|
|
|
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
25 |
|
08:45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
09:00 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
09:30 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
25 |
|
10:00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
10:30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
11:00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
11:30 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
25 |
|
11:45 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
25 |
|
12:00 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
12:30 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
12:45 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
0,525 |
3 |
35 |
0,315 |
4 |
10 |
55 |
14:30 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
15:00 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
15:30 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
16:00 |
0,015 |
2 |
25 |
|
|
|
|
|
|
|
|
|
|
16:30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
17:00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
18:00 |
|
|
|
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
25 |
|
18:15 |
|
|
|
0,105 |
2 |
25 |
|
|
|
0,105 |
3 |
40 |
|
18:30 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
19:00 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
19:30 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
20:00 |
|
|
|
0,105 |
2 |
25 |
|
|
|
|
|
|
|
20:30 |
|
|
|
|
|
|
1,05 |
3 |
35 |
0,42 |
4 |
10 |
55 |
20:45 |
|
|
|
0,105 |
2 |
25 |
|
|
|
|
|
|
|
20:46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
21:00 |
|
|
|
0,105 |
2 |
25 |
|
|
|
|
|
|
|
21:15 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
21:30 |
0,015 |
2 |
25 |
|
|
|
|
|
|
0,525 |
5 |
45 |
|
21:35 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
21:45 |
0,015 |
2 |
25 |
0,105 |
2 |
25 |
|
|
|
|
|
|
|
Qref |
0,345 |
2,100 |
2,100 |
2,100 |
h |
M |
L |
XL |
|||||||||
Qtap |
f |
Tm |
Tp |
Qtap |
f |
Tm |
Tp |
Qtap |
f |
Tm |
Tp |
|
kWh |
l/min |
°C |
°C |
kWh |
l/min |
°C |
°C |
kWh |
l/min |
°C |
°C |
|
07:00 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
07:05 |
1,4 |
6 |
40 |
|
1,4 |
6 |
40 |
|
|
|
|
|
07:15 |
|
|
|
|
|
|
|
|
1,82 |
6 |
40 |
|
07:26 |
|
|
|
|
|
|
|
|
0,105 |
3 |
25 |
|
07:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
|
|
|
|
07:45 |
|
|
|
|
0,105 |
3 |
25 |
|
4,42 |
10 |
10 |
40 |
08:01 |
0,105 |
3 |
25 |
|
|
|
|
|
0,105 |
3 |
25 |
|
08:05 |
|
|
|
|
3,605 |
10 |
10 |
40 |
|
|
|
|
08:15 |
0,105 |
3 |
25 |
|
|
|
|
|
0,105 |
3 |
25 |
|
08:25 |
|
|
|
|
0,105 |
3 |
25 |
|
|
|
|
|
08:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
08:45 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
09:00 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
09:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
10:00 |
|
|
|
|
|
|
|
|
0,105 |
3 |
25 |
|
10:30 |
0,105 |
3 |
10 |
40 |
0,105 |
3 |
10 |
40 |
0,105 |
3 |
10 |
40 |
11:00 |
|
|
|
|
|
|
|
|
0,105 |
3 |
25 |
|
11:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
11:45 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
12:00 |
|
|
|
|
|
|
|
|
|
|
|
|
12:30 |
|
|
|
|
|
|
|
|
|
|
|
|
12:45 |
0,315 |
4 |
10 |
55 |
0,315 |
4 |
10 |
55 |
0,735 |
4 |
10 |
55 |
14:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
15:00 |
|
|
|
|
|
|
|
|
0,105 |
3 |
25 |
|
15:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
16:00 |
|
|
|
|
|
|
|
|
0,105 |
3 |
25 |
|
16:30 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
17:00 |
|
|
|
|
|
|
|
|
0,105 |
3 |
25 |
|
18:00 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
18:15 |
0,105 |
3 |
40 |
|
0,105 |
3 |
40 |
|
0,105 |
3 |
40 |
|
18:30 |
0,105 |
3 |
40 |
|
0,105 |
3 |
40 |
|
0,105 |
3 |
40 |
|
19:00 |
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
0,105 |
3 |
25 |
|
19:30 |
|
|
|
|
|
|
|
|
|
|
|
|
20:00 |
|
|
|
|
|
|
|
|
|
|
|
|
20:30 |
0,735 |
4 |
10 |
55 |
0,735 |
4 |
10 |
55 |
0,735 |
4 |
10 |
55 |
20:45 |
|
|
|
|
|
|
|
|
|
|
|
|
20:46 |
|
|
|
|
|
|
|
|
4,42 |
10 |
10 |
40 |
21:00 |
|
|
|
|
3,605 |
10 |
10 |
40 |
|
|
|
|
21:15 |
0,105 |
3 |
25 |
|
|
|
|
|
0,105 |
3 |
25 |
|
21:30 |
1,4 |
6 |
40 |
|
0,105 |
3 |
25 |
|
4,42 |
10 |
10 |
40 |
21:35 |
|
|
|
|
|
|
|
|
|
|
|
|
21:45 |
|
|
|
|
|
|
|
|
|
|
|
|
Qref |
5,845 |
11,655 |
19,07 |
h |
XXL |
|||
Qtap |
f |
Tm |
Tp |
|
kWh |
l/min |
°C |
°C |
|
07:00 |
0,105 |
3 |
25 |
|
07:05 |
|
|
|
|
07:15 |
1,82 |
6 |
40 |
|
07:26 |
0,105 |
3 |
25 |
|
07:30 |
|
|
|
|
07:45 |
6,24 |
16 |
10 |
40 |
08:01 |
0,105 |
3 |
25 |
|
08:05 |
|
|
|
|
08:15 |
0,105 |
3 |
25 |
|
08:25 |
|
|
|
|
08:30 |
0,105 |
3 |
25 |
|
08:45 |
0,105 |
3 |
25 |
|
09:00 |
0,105 |
3 |
25 |
|
09:30 |
0,105 |
3 |
25 |
|
10:00 |
0,105 |
3 |
25 |
|
10:30 |
0,105 |
3 |
10 |
40 |
11:00 |
0,105 |
3 |
25 |
|
11:30 |
0,105 |
3 |
25 |
|
11:45 |
0,105 |
3 |
25 |
|
12:00 |
|
|
|
|
12:30 |
|
|
|
|
12:45 |
0,735 |
4 |
10 |
55 |
14:30 |
0,105 |
3 |
25 |
|
15:00 |
0,105 |
3 |
25 |
|
15:30 |
0,105 |
3 |
25 |
|
16:00 |
0,105 |
3 |
25 |
|
16:30 |
0,105 |
3 |
25 |
|
17:00 |
0,105 |
3 |
25 |
|
18:00 |
0,105 |
3 |
25 |
|
18:15 |
0,105 |
3 |
40 |
|
18:30 |
0,105 |
3 |
40 |
|
19:00 |
0,105 |
3 |
25 |
|
19:30 |
|
|
|
|
20:00 |
|
|
|
|
20:30 |
0,735 |
4 |
10 |
55 |
20:45 |
|
|
|
|
20:46 |
6,24 |
16 |
10 |
40 |
21:00 |
|
|
|
|
21:15 |
0,105 |
3 |
25 |
|
21:30 |
6,24 |
16 |
10 |
40 |
21:35 |
|
|
|
|
21:45 |
|
|
|
|
Qref |
24,53 |