COMMISSION DECISION (EU) 2020/1804
of 27 November 2020
establishing the EU Ecolabel criteria for electronic displays
(notified under document C(2020) 8156)
(Text with EEA relevance)
Article 1
Article 2
Article 3
Article 4
Article 5
Article 6
Article 7
Article 8
ANNEX
EU Ecolabel criteria for awarding the EU Ecolabel to electronic displays
FRAMEWORK
Aims of the criteria
EU ECOLABEL CRITERIA
Criterion 1 – Energy consumption
1.1
Energy savings
1.2
Power management
Criterion 2 – Restricted substances
2.1
Excluded or limited substances
Group 1 hazards |
||||||||||
|
||||||||||
Group 2 hazards |
||||||||||
|
||||||||||
Group 3 hazards |
||||||||||
|
2.1(a)
Restrictions on Substances of Very High Concern (SVHCs)
Printed Circuit Boards (Printed Wiring Boards, populated motherboards, power boards (power supply units) and module boards ) >10 cm2 |
Electrical wiring/cables (aggregated) |
External cables (Power cable (AC and DC power cords), modem cable and LAN cable if applicable, HDMI cable and RCA cable) |
External housing (Back cover, front cover (bezel decoration) and stands) |
External housing of remote control |
LED backlights (LED arrays) |
2.1(b)
Restrictions on the presence of specific substances
Substance group |
Scope of restriction (substances and sub-assemblies/component parts) |
Concentration limits (where applicable) |
|||||||||||||||||||||||||||||||||||
|
Exemption 8b in accordance with Directive 2011/65/EU of the European Parliament and of the Council(8)relating to the use of cadmium in electrical contacts shall not be permitted. |
0,01 % w/w Test method: IEC 62321-5 |
|||||||||||||||||||||||||||||||||||
|
The following organotin stabiliser compounds classified with Group 1 and 2 hazards shall not be present in external cables:
|
n/a |
|||||||||||||||||||||||||||||||||||
External housing of the display shall not contain the following colourants: Azo dyes that may cleave to the carcinogenic aryl amines listed in Appendix 8 of the Regulation (EC) No 1907/2006, and/or Colourant compounds included in the IEC 62474 declarable substances list. |
n/a |
||||||||||||||||||||||||||||||||||||
Polycyclic Aromatic Hydrocarbons (PAHs) classified with Group 1 and 2 hazards shall not be present at concentrations greater than or equal to individual and sum total concentration limits in any external plastic or man-made rubber surfaces of: External cables External housing of the remote control Rubber parts of the remote control The presence and concentration of the following PAHs shall be verified: PAHs restricted by the Regulation (EC) No 1907/2006:
Additional PAHs subject to restriction:
|
The individual concentration limits for PAHs restricted under Regulation (EC) No 1907/2006 shall be 1 mg/kg The sum total concentration limit for the 18 listed PAHs shall not be greater than 10 mg/kg Test method: AfPS GS 2014:01 PAK. |
||||||||||||||||||||||||||||||||||||
|
Biocidal products intended to provide an anti-bacterial function shall not be incorporated into External housing and rubber parts of the remote control. |
n/a |
|||||||||||||||||||||||||||||||||||
|
Exemption 3 in accordance with Directive 2011/65/EU relating to the use of mercury in cold cathode fluorescent lamps and external electrode fluorescent lamps (CCFL and EEFL) shall not be permitted. |
n/a |
|||||||||||||||||||||||||||||||||||
|
Arsenic and its compounds shall not be used in the manufacturing of LCD display unit glass and screen cover glass. |
0,0050 % w/w |
|||||||||||||||||||||||||||||||||||
|
Plastic parts >25 g must not contain chlorinated polymers. Note: For this specific sub-requirement, plastic cable housing is not considered as a ‘plastic part’. |
n/a |
|||||||||||||||||||||||||||||||||||
|
Diisononyl phthalate (DINP), Diisodecyl phthalate (DIDP) shall not be used in external power cables. |
n/a |
2.1(c)
Restrictions on substances classified under Regulation (EC) No 1272/2008
Parts containing flame retardants |
||||||
|
||||||
Parts containing plasticisers |
||||||
|
Derogations for the use of hazardous flame retardants and plasticisers
Substance /mixture type |
Applicability |
Derogated hazard class, category and hazard statement code and derogation conditions |
Flame retardants |
Printed Circuit Boards |
Flame retardants classified with Group 3 hazards and TBBPA (classified with Group 2) are derogated for use. |
External cables |
Flame retardant and its synergist classified with Group 3 hazard and Antimony trioxide (Sb2O3) classified with Group 2 hazards are derogated for use. |
|
External housing of the display |
Flame retardants and their synergists classified with Group 2 and 3 hazards are derogated for use. |
|
Plasticisers |
External cables, internal electrical wiring and external housing of the display |
Plasticisers classified with Group 3 hazards are derogated for use. |