COMMISSION DECISION (EU) 2022/1244
of 13 July 2022
establishing the EU Ecolabel criteria for growing media and soil improvers
(notified under document C(2022) 4758)
(Text with EEA relevance)
Article 1
Article 2
Article 3
Article 4
Article 5
Article 6
Article 7
Article 8
ANNEX
EU Ecolabel criteria for awarding the EU Ecolabel to growing media and soil improvers
FRAMEWORK
EU ECOLABEL CRITERIA
Criterion |
Growing media |
Soil improvers |
1 – Components |
x |
x |
1.1 – Organic components of the product |
x |
x |
2 – Mineral components |
x |
x |
2.1 – Energy consumption and CO2 emissions during the manufacture of mineral growing media |
x |
|
2.2 – Sources of mineral extraction |
x |
x |
2.3 – Mineral growing media use and after use |
x |
|
3 – Organic components and recycled/recovered materials in growing media |
x |
|
4 – Restricted substances |
x |
x |
4.1 – Limits for heavy metals |
x |
x |
4.2 – Limits for polycyclic aromatic hydrocarbons (PAHs) |
x |
x |
4.3 – Restrictions on substances and mixtures classified as hazardous under Regulation (EC) No 1272/2008 of the European Parliament and of the Council(1) |
x |
x |
4.4 – Restrictions on substances of very high concern (SVHCs) as identified under Regulation (EC) No 1907/2006 of the European Parliament and of the Council(2) |
x |
x |
4.5 – Microbiological criteria |
x |
x |
5 – Fitness for use |
x |
x |
5.1 – Stability |
x |
x |
5.2 – Macroscopic impurities |
x |
x |
5.3 – Organic matter and dry matter in soil improvers |
|
x |
5.4 – Viable weed seeds and plant propagules |
x |
x |
5.5 – Plant response |
x |
x |
6 – Growing media features |
x |
|
6.1 – Electrical conductivity |
x |
|
6.2 – Sodium content |
x |
|
6.3 – Chloride content |
x |
|
7 – Provision of information |
x |
x |
7.1 – Soil improvers |
|
x |
7.2 – Growing media |
x |
|
8 – Information appearing on the EU Ecolabel |
x |
x |
Assessment and verification requirements
Criterion 1 – Components
Criterion 1.1 – Organic components of the product
Assessment and verification
Criterion 2 – Mineral components
Criterion 2.1 – Energy consumption and CO
2
emissions during the manufacture of mineral growing media
Assessment and verification
Criterion 2.2 – Sources of mineral extraction
Assessment and verification
Criterion 2.3 – Mineral growing media use and after use
Assessment and verification
Criterion 3 – Organic components and recycled/recovered materials in growing media
Assessment and verification
Criterion 4 –Restricted substances
Criterion 4.1 – Limits for heavy metals
Criterion 4.1(a) – Limits for heavy metals in soil improvers
Heavy metal |
Maximum content in the product (mg/kg DM) |
Cadmium (Cd) |
1 |
Chromium total (Cr total) |
100 |
Copper (Cu) |
200 |
Mercury (Hg) |
0,45 |
Nickel (Ni) |
40 |
Lead (Pb) |
100 |
Zinc (Zn) |
300 |
Inorganic Arsenic (As) |
10 |
Criterion 4.1(b) – Limits for heavy metals in growing media
Heavy metal |
Maximum content in the product (mg/kg DM) |
|
Mineral growing media |
Growing media other than mineral growing media |
|
Cadmium (Cd) |
1,3 |
1,3 |
Chromium total (Cr total) |
310 |
100 |
Chromium VI (Cr VI) |
2 |
Not applicable |
Copper (Cu) |
200 |
200 |
Mercury (Hg) |
0,45 |
0,45 |
Nickel (Ni) |
40 |
40 |
Lead (Pb) |
100 |
100 |
Zinc (Zn) |
300 |
300 |
Inorganic arsenic (As) |
10 |
10 |
Assessment and verification
Criterion 4.2 – Limits for polycyclic aromatic hydrocarbons (PAHs)
Pollutant |
Maximum content in the product (mg/kg DM) |
PAH16 |
6 |
PAH16 = sum of naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[ghi]perylene. |
Assessment and verification
Criterion 4.3 – Restrictions on substances and mixtures classified as hazardous under Regulation (EC) No 1272/2008
Assessment and verification
Criterion 4.4 – Restrictions on substances of very high concern (SVHCs) as identified under Regulation (EC) No 1907/2006
Assessment and verification
Criterion 4.5 – Microbiological criteria
Micro-organisms to be tested |
Sampling plans |
Limit |
||
n |
c |
m |
M |
|
Salmonella spp. |
5 |
0 |
0 |
Absence in 25 g or 25 ml |
Escherichia coli or Enterococcaceae |
5 |
5 |
0 |
1 000 CFU in 1 g or 1 ml |
CFU = colony-forming units |
Assessment and verification
Parameter |
Test method |
E. coli |
CEN/TR 16193 or ISO 16649-2 or EN ISO 9308-3 |
Salmonella spp. |
EN ISO 6579 or CEN/TR 15215 |
Enterococcacea |
EN 15788 or EN ISO 7899-1 or BEA method |
Criterion 5 – Fitness for use
Criterion 5.1 – Stability
Stability parameter |
Requirement |
Maximum Respirometric index |
15 mmol O2/kg organic matter/h |
Minimum Rottegrad, where applicable |
IV (self-heating test temperature rise of maximum 20 °C above ambient temperature) |
Stability parameter |
Requirement |
Maximum Respirometric index |
25 mmol O2/kg organic matter/h |
Minimum Rottegrad, where applicable |
III (self-heating test temperature rise of maximum 30 °C above ambient temperature) |
Assessment and verification
Parameter |
Test method |
Respirometric index |
EN 16087-1 |
Rottegrad |
EN 16087-2 |
Criterion 5.2 – Macroscopic impurities
Assessment and verification
Criterion 5.3 – Organic matter and dry matter in soil improvers
Assessment and verification
Parameter |
Test method |
Dry matter (% FW) |
EN 13040 |
Organic matter as loss on ignition (% dry mass) |
EN 13039 |
Total organic carbon (TOC) (% dry mass) |
EN 15936 |
Criterion 5.4 – Viable weed seeds and plant propagules
Assessment and verification
Criterion 5.5 – Plant response
Assessment and verification
Criterion 6 – Growing media features
Criterion 6.1 – Electrical conductivity
Assessment and verification
Criterion 6.2 – Sodium content
Assessment and verification
Criterion 6.3 – Chloride content
Assessment and verification
Criterion 7 – Provision of information
Criterion 7.1 – Soil improvers
Criterion 7.2 – Growing media
Assessment and verification
Criterion 8 – Information appearing on the EU Ecolabel
Assessment and verification
Appendix 1
Sampling and test frequency for the application year
Type of plant |
Criterion |
Annual input/output |
Test frequency |
||||||||||||||||
Type 1: Waste/animal –by-product treatment plants |
|
Input (t) ≤ 3 000 |
1 every 1 000 tonnes input material rounded to the next integer |
||||||||||||||||
3 000 < input (t) < 20 000 |
4 (one sample every season) |
||||||||||||||||||
Input (t) ≥ 20 000 |
number of analyses per year = amount of annual input material (in tonnes)/10 000 tonne + 1 |
||||||||||||||||||
|
Input (t) ≤ 3 000 |
1 |
|||||||||||||||||
3 001 < input (t) < 10 000 |
2 |
||||||||||||||||||
10 001 < input (t) < –20 000 |
3 |
||||||||||||||||||
20 001 < input (t) < 40 000 |
4 |
||||||||||||||||||
40 001 < input (t) < 60 000 |
5 |
||||||||||||||||||
60 001 < input (t) < 80 000 |
6 |
||||||||||||||||||
80 001 < input (t) < 100 000 |
7 |
||||||||||||||||||
100 001 < input (t) < 120 000 |
8 |
||||||||||||||||||
120 001 < input (t) < 140 000 |
9 |
||||||||||||||||||
140 001 < input (t) < 160 000 |
10 |
||||||||||||||||||
160 001 < input (t) < 180 000 |
11 |
||||||||||||||||||
Input (t) ≥ 180 000 |
12 |
||||||||||||||||||
Type 2: Product manufacture plants using materials derived from waste/animal by-product, except those that are waste treatment plants |
|
Output (m3) ≤ 5 000 |
Representative combined samples from 2 different batches in accordance with EN 12579(1) |
||||||||||||||||
Output (m3) > 5 000 |
Representative combined samples from 4 different batches in accordance with EN 12579 |
||||||||||||||||||
|
Output (m3) ≤ 5 000 |
Representative combined samples from 1 different batch in accordance with EN 12579 |
|||||||||||||||||
Output (m3) > 5 000 |
Representative combined samples from 2 different batches EN 12579 |
||||||||||||||||||
Type 3: Product manufacture plants NOT using materials derived from waste/animal by-product |
|
Output (m3) ≤ 5 000 |
Representative combined samples from 1 batch in accordance with EN 12579 |
||||||||||||||||
Output (m3) > 5 000 |
Representative combined samples from 2 different batches in accordance with EN 12579 |
||||||||||||||||||
|
Regardless of the input/output |
Representative combined samples from 1 batch in accordance with EN 12579 |
Appendix 2
Sampling and test frequency for the following years
Type of plant |
Criteria |
Annual input/output |
Test frequency |
||||||||||||||||
Type 1: Waste/animal by-product treatment plants |
|
Input (t) ≤ 1 000 |
1 |
||||||||||||||||
Input (t)> 1 000 |
number of analyses per year = amount of annual input material (in tonnes)/10 000 tonne + 1 |
||||||||||||||||||
Minimum 2 and maximum 12 |
|||||||||||||||||||
|
Input (t) ≤ 10 000 |
0,25 (once every 4 years) |
|||||||||||||||||
10 001 < input (t) < 25 000 |
0,5 (once every 2 years) |
||||||||||||||||||
25 001 < input (t) < 50 000 |
1 |
||||||||||||||||||
50 001 < input (t) < 100 000 |
2 |
||||||||||||||||||
100 001 < input (t) < 150 000 |
3 |
||||||||||||||||||
150 001 < input (t) < 200 000 |
4 |
||||||||||||||||||
200 001 < input (t) < 250 000 |
5 |
||||||||||||||||||
250 001 < input (t) < 300 000 |
6 |
||||||||||||||||||
300 001 < input (t) < 350 000 |
7 |
||||||||||||||||||
350 001 < input (t) < 400 000 |
8 |
||||||||||||||||||
400 001 < input (t) < 450 000 |
9 |
||||||||||||||||||
450 001 < input (t) < 500 000 |
10 |
||||||||||||||||||
500 001 < input (t) < 550 000 |
11 |
||||||||||||||||||
Input (t) ≥ 550 000 |
12 |
||||||||||||||||||
Type 2: Product manufacture plants using materials derived from waste/animal by-product, except those that are waste treatment plants |
|
Output (m3) ≤ 5 000 |
Representative combined samples from 1 different batch in accordance with EN 12579 |
||||||||||||||||
Output (m3) > 5 000 |
Representative combined samples from 2 different batches in accordance with EN 12579 |
||||||||||||||||||
|
Output (m3) ≤ 15 000 |
Representative combined samples from 1 batch in accordance with EN 12579, once every 4 years |
|||||||||||||||||
15 000 < Output (m3) < 40 000 |
Representative combined samples from 1 batch in accordance with EN 12579, every two years |
||||||||||||||||||
Output (m3) ≥ 40 000 |
Representative combined samples from 1 batch in accordance with EN 12579, every year |
||||||||||||||||||
Type 3: Product manufacture plants NOT using materials derived from waste/animal by-product |
|
Regardless of the input/output |
Representative combined samples from 1 batch in accordance with EN 12579 |
||||||||||||||||
|
Regardless of the input/output |
Representative combined samples from 1 batch in accordance with EN 12579, once every 4 years |