COMMISSION DECISION
of 6 May 2010
on harmonised technical conditions of use in the 790-862 MHz frequency band for terrestrial systems capable of providing electronic communications services in the European Union
(notified under document C(2010) 2923)
(Text with EEA relevance)
(2010/267/EU)
Article 1
Article 2
Article 3
Article 4
ANNEX
PARAMETERS REFERRED TO IN ARTICLES
A.
General parameters
B.
Technical conditions for FDD or TDD base stations (BS)
Frequency range of out-of-block emissions |
Maximum mean out-of-block EIRP |
Measurement bandwidth |
Frequencies used for FDD uplink |
–49,5 dBm |
5 MHz |
Frequencies used for TDD |
–49,5 dBm |
5 MHz |
Frequency range of out-of-block emissions |
Maximum mean out-of-block EIRP |
Measurement bandwidth |
– 10 to – 5 MHz from lower block edge |
18 dBm |
5 MHz |
– 5 to 0 MHz from lower block edge |
22 dBm |
5 MHz |
0 to + 5 MHz from upper block edge |
22 dBm |
5 MHz |
+ 5 to + 10 MHz from upper block edge |
18 dBm |
5 MHz |
Remaining FDD downlink frequencies |
11 dBm |
1 MHz |
Frequency range of out-of-block emissions |
Maximum mean out-of-block EIRP |
Measurement Bandwidth |
Guard band between broadcasting band edge at 790 MHz and FDD downlink band edge(5) |
17,4 dBm |
1 MHz |
Guard band between broadcasting band edge at 790 MHz and TDD band edge |
15 dBm |
1 MHz |
Guard band between FDD downlink band edge and FDD uplink band edge (duplex gap)(6) |
15 dBm |
1 MHz |
Guard band between FDD downlink band edge and TDD band edge |
15 dBm |
1 MHz |
Guard band between FDD uplink band edge and TDD band edge |
15 dBm |
1 MHz |
Case |
Condition on base station in-block EIRP, P dBm/10 MHz |
Maximum mean out-of-block EIRP |
Measurement bandwidth |
|
A |
For TV channels where broadcasting is protected |
P ≥ 59 |
0 dBm |
8 MHz |
36 ≤ P < 59 |
(P – 59) dBm |
8 MHz |
||
P < 36 |
– 23 dBm |
8 MHz |
||
B |
For TV channels where broadcasting is subject to an intermediate level of protection |
P ≥ 59 |
10 dBm |
8 MHz |
36 ≤ P < 59 |
(P – 49) dBm |
8 MHz |
||
P < 36 |
–13 dBm |
8 MHz |
||
C |
For TV channels where broadcasting is not protected |
No conditions |
22 dBm |
8 MHz |
C.
Technical conditions for FDD or TDD terminal stations (TS)
Maximum mean in-block power |
23 dBm(7) |