Regulation No 87 of the Economic Commission for Europe of the United Nations (UN/ECE) — Uniform provisions concerning the approval of daytime running lamps for power-driven vehicles
1. SCOPE
2. DEFINITIONS
3. APPLICATION FOR APPROVAL
4. MARKINGS
5. APPROVAL
5.1. General
5.2. Composition of the approval mark
5.3. Arrangement of the approval mark
5.3.1. Independent lamps
5.3.2. Grouped, combined or reciprocally incorporated lamps
5.3.3. Lamps reciprocally incorporated with other lamps, of which the lens may also be used for other types of devices
6. GENERAL SPECIFICATIONS
7. INTENSITY OF LIGHT
8. APPARENT SURFACE
9. COLOUR OF LIGHT
10. TEST PROCEDURE
11. HEAT RESISTANCE TEST
12. MODIFICATIONS OF A TYPE OF DAYTIME RUNNING LAMP AND EXTENSION OF APPROVAL
13. CONFORMITY OF PRODUCTION
14. PENALTIES FOR NON-CONFORMITY OF PRODUCTION
15. PRODUCTION DEFINITELY DISCONTINUED
16. NAMES AND ADDRESSES OF TECHNICAL SERVICES RESPONSIBLE FOR CONDUCTING APPROVAL TESTS AND OF ADMINISTRATIVE DEPARTMENTS
ANNEX 1
COMMUNICATION
(Maximum format: A4 (210 × 297 mm))
ANNEX 2
EXAMPLE OF ARRANGEMENT OF THE APPROVAL MARK
Figure 1
Examples of possible markings for grouped lamps situated at the front of the vehicle
Figure 2
Lamp reciprocally incorporated with a headlamp
Figure 3
ANNEX 3
PHOTOMETRIC MEASUREMENTS
4. Photometric measurement of lamps
5. Table of standard light distribution
Figure 4
Light source modules
ANNEX 4
Minimum requirements for conformity of production control procedures
1. GENERAL
2. MINIMUM REQUIREMENTS FOR VERIFICATION OF CONFORMITY BY THE MANUFACTURER
2.1. Nature of tests
2.2. Methods used in tests
2.3. Nature of sampling
2.4. Measured and recorded photometric characteristics
2.5. Criteria governing acceptability
ANNEX 5
MINIMUM REQUIREMENTS FOR SAMPLING BY AN INSPECTOR
1. GENERAL
2. FIRST SAMPLING
2.1. The conformity is not contested
A1: |
one lamp |
0 per cent |
one lamp not more than |
20 per cent |
|
A2: |
both lamps more than |
0 per cent |
but not more than |
20 per cent |
|
go to sample B |
|
B1: |
both lamps |
0 per cent |
2.2. The conformity is contested
A3: |
one lamp not more than |
20 per cent |
one lamp more than |
20 per cent |
|
but not more than |
30 per cent |
B2: |
in the case of A2 |
|
one lamp more than |
0 per cent |
|
but not more than |
20 per cent |
|
one lamp not more than |
20 per cent |
|
B3: |
in the case of A2 |
|
one lamp |
0 per cent |
|
one lamp more than |
20 per cent |
|
but not more than |
30 per cent |
2.3. Approval withdrawn
A4: |
one lamp not more than |
20 per cent |
one lamp more than |
30 per cent |
|
A5: |
both lamps more than |
20 per cent |
B4: |
in the case of A2 |
|
one lamp more than |
0 per cent |
|
but not more than |
20 per cent |
|
one lamp more than |
20 per cent |
|
B5: |
in the case of A2 |
|
both lamps more than |
20 per cent |
|
B6: |
in the case of A2 |
|
one lamp |
0 per cent |
|
one lamp more than |
30 per cent |
3. REPEATED SAMPLING
3.1. The conformity is not contested
C1: |
one lamp |
0 per cent |
one lamp not more than |
20 per cent |
|
C2: |
both lamps more than |
0 per cent |
but not more than |
20 per cent |
|
go to sample D |
|
D1: |
in the case of C2 |
|
both lamps |
0 per cent |
3.2. The conformity is contested
D2: |
in the case of C2 |
|
one lamp more than |
0 per cent |
|
but not more than |
20 per cent |
|
one lamp not more than |
20 per cent |
3.3. Approval withdrawn
C3: |
one lamp not more than |
20 per cent |
one lamp more than |
20 per cent |
|
C4: |
both lamps more than |
20 per cent |
D3: |
in the case of C2 |
|
one lamp 0 or more than |
0 per cent |
|
one lamp more than |
20 per cent |