COMMISSION REGULATION (EU) No 327/2011
of 30 March 2011
implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125 W and 500 kW
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements
Article 4
Conformity assessment
Article 5
Verification procedure for market surveillance purposes
Article 6
Indicative benchmarks
Article 7
Revision
Article 8
Entry into force
ANNEX I
ECODESIGN REQUIREMENTS FOR FANS
1.
Definitions for the purposes of Annex I
2.
Fan energy efficiency requirements
Fan types |
Measurement category (A-D) |
Efficiency category (static or total) |
Power range P in kW |
Target energy efficiency |
Efficiency grade (N) |
Axial fan |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
36 |
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
50 |
|
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
Centrifugal forward curved fan and centrifugal radial bladed fan |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
37 |
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
42 |
|
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
Centrifugal backward curved fan without housing |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
58 |
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
Centrifugal backward curved fan with housing |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
58 |
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
61 |
|
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
Mixed flow fan |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
47 |
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
58 |
|
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
Cross flow fan |
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 1,14 · ln(P) – 2,6 + N |
13 |
10 < P ≤ 500 |
ηtarget = N |
Fan types |
Measurement category (A-D) |
Efficiency category (static or total) |
Power range P in kW |
Target energy efficiency |
Efficiency grade (N) |
Axial fan |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
40 |
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
58 |
|
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
Centrifugal forward curved fan and centrifugal radial bladed fan |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
44 |
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 2,74 · ln(P) – 6,33 + N |
49 |
|
10 < P ≤ 500 |
ηtarget = 0,78 · ln(P) – 1,88 + N |
||||
Centrifugal backward curved fan without housing |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
62 |
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
Centrifugal backward curved fan with housing |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
61 |
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
64 |
|
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
Mixed flow fan |
A, C |
static |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
50 |
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 4,56 · ln(P) – 10,5 + N |
62 |
|
10 < P ≤ 500 |
ηtarget = 1,1 · ln(P) – 2,6 + N |
||||
Cross flow fan |
B, D |
total |
0,125 ≤ P ≤ 10 |
ηtarget = 1,14 · ln(P) – 2,6 + N |
21 |
10 < P ≤ 500 |
ηtarget = N |
3.
Product information requirements on fans
ANNEX II
MEASUREMENTS AND CALCULATIONS
1.
Definitions for the purposes of Annex II
2.
Measurement method
3.
Calculation method
4.
Methodology for calculating the target energy efficiency
Power range P from 0,125 kW to 10 kW |
Power range P from 10 kW to 500 kW |
ηtarget = 2,74 · ln(P) – 6,33 + N |
ηtarget = 0,78 · ln(P) – 1,88 + N |
Power range P from 0,125 kW to 10 kW |
Power range P from 10 kW to 500 kW |
ηtarget = 4,56 · ln(P) – 10,5 + N |
ηtarget = 1,1 · ln(P) – 2,6 + N |
Power range P from 0,125 kW to 10 kW |
Power range P from 10 kW to 500 kW |
ηtarget = 1,14 · ln(P) – 2,6 + N |
ηtarget = N |
5.
Applying the target energy efficiency
ANNEX III
VERIFICATION PROCEDURE FOR MARKET SURVEILLANCE PURPOSES
ANNEX IV
INDICATIVE BENCHMARKS REFERRED TO IN ARTICLE 6
Fan types |
Measurement category (A-D) |
Efficiency category (static or total) |
Efficiency grade |
Axial fan |
A, C |
static |
65 |
B, D |
total |
75 |
|
Centrifugal forward curved fan and centrifugal radial bladed fan |
A, C |
static |
62 |
B, D |
total |
65 |
|
Centrifugal backward curved fan without housing |
A, C |
static |
70 |
Centrifugal backward curved fan with housing |
A, C |
static |
72 |
B, D |
total |
75 |
|
Mixed flow fan |
A, C |
static |
61 |
B, D |
total |
65 |
|
Cross flow fan |
B, D |
total |
32 |