COMMISSION REGULATION (EU) 2015/1185
of 24 April 2015
implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for solid fuel local space heaters
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements and timetable
Article 4
Conformity assessment
Article 5
Verification procedure for market surveillance purposes
Article 6
Indicative benchmarks
Article 7
Review
Article 8
Transitional provisions
Article 9
Entry into force
ANNEX I
Definitions applicable for Annexes II to V
ANNEX II
Ecodesign requirements
1.
Specific ecodesign requirements for seasonal space heating energy efficiency
2.
Specific ecodesign requirements for emissions.
3.
Requirements for product information
Model identifier(s): |
||||||||||||||||||
Indirect heating functionality:[yes/no] |
||||||||||||||||||
Direct heat output: …(kW) |
||||||||||||||||||
Indirect heat output: …(kW) |
||||||||||||||||||
Fuel |
Preferred fuel (only one): |
Other suitable fuel(s): |
η s [x%]: |
Space heating emissions at nominal heat output(1) |
Space heating emissions at minimum heat output(1) (2) |
|||||||||||||
PM |
OGC |
CO |
NOx |
PM |
OGC |
CO |
NOx |
|||||||||||
[x] mg/Nm3 (13 % O2) |
[x] mg/Nm3 (13 % O2) |
|||||||||||||||||
Wood logs with moisture content ≤ 25 % |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Compressed wood with moisture content < 12 % |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Other woody biomass |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Non-woody biomass |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Anthracite and dry steam coal |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Hard coke |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Low temperature coke |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Bituminous coal |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Lignite briquettes |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Peat briquettes |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Blended fossil fuel briquettes |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Other fossil fuel |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Blended biomass and fossil fuel briquettes |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Other blend of biomass and solid fuel |
[yes/no] |
[yes/no] |
|
|
|
|
|
|
|
|
|
|||||||
Characteristics when operating with the preferred fuel only |
||||||||||||||||||
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
||||||||||
Heat output |
|
Useful efficiency (NCV as received) |
||||||||||||||||
Nominal heat output |
Pnom |
x |
kW |
Useful efficiency at nominal heat output |
ηth,nom |
x,x |
% |
|||||||||||
Minimum heat output (indicative) |
Pmin |
[x,x/N.A.] |
kW |
Useful efficiency at minimum heat output (indicative) |
ηth,min |
[x,x/N.A.] |
% |
|||||||||||
Auxiliary electricity consumption |
|
Type of heat output/room temperature control (select one) |
||||||||||||||||
At nominal heat output |
elmax |
x,xxx |
kW |
single stage heat output, no room temperature control |
[yes/no] |
|
||||||||||||
At minimum heat output |
elmin |
x,xxx |
kW |
two or more manual stages, no room temperature control |
[yes/no] |
|||||||||||||
In standby mode |
elSB |
x,xxx |
kW |
with mechanic thermostat room temperature control |
[yes/no] |
|||||||||||||
Permanent pilot flame power requirement |
with electronic room temperature control |
[yes/no] |
||||||||||||||||
Pilot flame power requirement (if applicable) |
Ppilot |
[x,xxx/N.A.] |
kW |
with electronic room temperature control plus day timer |
[yes/no] |
|||||||||||||
|
with electronic room temperature control plus week timer |
[yes/no] |
||||||||||||||||
Other control options (multiple selections possible) |
||||||||||||||||||
room temperature control, with presence detection |
[yes/no] |
|
||||||||||||||||
room temperature control, with open window detection |
[yes/no] |
|||||||||||||||||
with distance control option |
[yes/no] |
|||||||||||||||||
Contact details |
Name and address of the manufacturer or its authorised representative. |
ANNEX III
Measurements and calculations
2.
General conditions for measurements and calculations
3.
General conditions for seasonal space heating energy efficiency
4.
General conditions for emissions
5.
Specific conditions for seasonal space heating energy efficiency
If the product is equipped with (only one option may apply): |
F(2) |
single stage heat output, no room temperature control |
0,0 % |
two or more manual stages, no temperature control |
1,0 % |
with mechanic thermostat room temperature control |
2,0 % |
with electronic room temperature control |
4,0 % |
with electronic room temperature control plus day timer |
6,0 % |
with electronic room temperature control plus week timer |
7,0 % |
If the product is equipped with (multiple options may apply): |
F(3) |
room temperature control with presence detection |
1,0 % |
room temperature control with open window detection |
1,0 % |
with distance control option |
1,0 % |