Commission Delegated Regulation (EU) 2015/1186 of 24 April 2015 supplementing Dir... (32015R1186)
Commission Delegated Regulation (EU) 2015/1186 of 24 April 2015 supplementing Dir... (32015R1186)
COMMISSION DELEGATED REGULATION (EU) 2015/1186
of 24 April 2015
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of local space heaters
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Responsibilities of suppliers and timetable
Article 4
Responsibilities of dealers
Article 5
Measurement and calculation methods
Article 6
Verification procedure for market surveillance purposes
Article 7
Review
Article 8
Entry into force
ANNEX I
Definitions applicable for Annexes II to IX
ANNEX II
Energy efficiency classes
|
Energy efficiency class |
Energy efficiency index (EEI) |
|
A++ |
EEI ≥ 130 |
|
A+ |
107 ≤ EEI < 130 |
|
A |
88 ≤ EEI < 107 |
|
B |
82 ≤ EEI < 88 |
|
C |
77 ≤ EEI < 82 |
|
D |
72 ≤ EEI < 77 |
|
E |
62 ≤ EEI < 72 |
|
F |
42 ≤ EEI < 62 |
|
G |
EEI < 42 |
ANNEX III
The label
ANNEX IV
Product fiche
ANNEX V
Technical documentation
|
Model identifier(s): |
||||||||||
|
Indirect heating functionality:[yes/no] |
||||||||||
|
Direct heat output: …(kW) |
||||||||||
|
Indirect heat output: …(kW) |
||||||||||
|
Fuel |
Preferred fuel (only one): |
Other suitable fuel(s): |
||||||||
|
Wood logs with moisture content ≤ 25 % |
[yes/no] |
[yes/no] |
||||||||
|
Compressed wood with moisture content < 12 % |
[yes/no] |
[yes/no] |
||||||||
|
Other woody biomass |
[yes/no] |
[yes/no] |
||||||||
|
Non-woody biomass |
[yes/no] |
[yes/no] |
||||||||
|
Anthracite and dry steam coal |
[yes/no] |
[yes/no] |
||||||||
|
Hard coke |
[yes/no] |
[yes/no] |
||||||||
|
Low temperature coke |
[yes/no] |
[yes/no] |
||||||||
|
Bituminous coal |
[yes/no] |
[yes/no] |
||||||||
|
Lignite briquettes |
[yes/no] |
[yes/no] |
||||||||
|
Peat briquettes |
[yes/no] |
[yes/no] |
||||||||
|
Blended fossil fuel briquettes |
[yes/no] |
[yes/no] |
||||||||
|
Other fossil fuel |
[yes/no] |
[yes/no] |
||||||||
|
Blended biomass and fossil fuel briquettes |
[yes/no] |
[yes/no] |
||||||||
|
Other blend of biomass and solid fuel |
[yes/no] |
[yes/no] |
||||||||
|
Characteristics when operating with the preferred fuel |
||||||||||
|
Seasonal space heating energy efficiency η s [%]: |
||||||||||
|
Energy Efficiency Index (EEI): |
||||||||||
|
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
||
|
Heat output |
|
Useful efficiency (NCV as received) |
||||||||
|
Nominal heat output |
Pnom |
x,x |
kW |
|
Useful efficiency at nominal heat output |
ηth,nom |
x,x |
% |
||
|
Minimum heat output (indicative) |
Pmin |
[x,x/N.A.] |
kW |
|
Useful efficiency at minimum heat output (indicative) |
ηth,min |
[x,x/N.A.] |
% |
||
|
|
|
|
|
|
|
|||||
|
Auxiliary electricity consumption |
|
Type of heat output/room temperature control (select one) |
||||||||
|
At nominal heat output |
elmax |
x,xxx |
kW |
|
single stage heat output, no room temperature control |
[yes/no] |
|
|||
|
At minimum heat output |
elmin |
x,xxx |
kW |
|
two or more manual stages, no room temperature control |
[yes/no] |
|
|||
|
In standby mode |
elSB |
x,xxx |
kW |
|
with mechanic thermostat room temperature control |
[yes/no] |
|
|||
|
|
|
with electronic room temperature control |
[yes/no] |
|
||||||
|
|
|
with electronic room temperature control plus day timer |
[yes/no] |
|
||||||
|
|
|
with electronic room temperature control plus week timer |
[yes/no] |
|
||||||
|
|
|
Other control options (multiple selections possible) |
||||||||
|
|
|
room temperature control, with presence detection |
[yes/no] |
|
||||||
|
|
|
room temperature control, with open window detection |
[yes/no] |
|
||||||
|
|
|
with distance control option |
[yes/no] |
|
||||||
|
Permanent pilot flame power requirement |
|
|
|
|
||||||
|
Pilot flame power requirement (if applicable) |
Ppilot |
[x,xxx/N.A.] |
kW |
|
|
|||||
|
Contact details |
Name and address of the supplier |
|||||||||
|
Model identifier(s): |
||||||||||
|
Indirect heating functionality:[yes/no] |
||||||||||
|
Direct heat output: …(kW) |
||||||||||
|
Indirect heat output: …(kW) |
||||||||||
|
Fuel |
|
|
|
|||||||
|
Select fuel type |
[gaseous/liquid] |
[specify] |
||||||||
|
|
|
|
|
|||||||
|
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
||
|
Heat output |
|
Useful efficiency (NCV) |
||||||||
|
Nominal heat output |
Pnom |
x,x |
kW |
|
Useful efficiency at nominal heat output |
ηth,nom |
x,x |
% |
||
|
Minimum heat output (indicative) |
Pmin |
[x,x/N.A.] |
kW |
|
Useful efficiency at minimum heat output (indicative) |
ηth,min |
[x,x/N.A.] |
% |
||
|
|
|
|
|
|
|
|||||
|
Auxiliary electricity consumption |
|
Type of heat output/room temperature control (select one) |
||||||||
|
At nominal heat output |
elmax |
x,xxx |
kW |
|
single stage heat output, no room temperature control |
[yes/no] |
|
|||
|
At minimum heat output |
elmin |
x,xxx |
kW |
|
two or more manual stages, no room temperature control |
[yes/no] |
|
|||
|
In standby mode |
elSB |
x,xxx |
kW |
|
with mechanic thermostat room temperature control |
[yes/no] |
|
|||
|
|
|
with electronic room temperature control |
[yes/no] |
|
||||||
|
|
|
with electronic room temperature control plus day timer |
[yes/no] |
|
||||||
|
|
|
with electronic room temperature control plus week timer |
[yes/no] |
|
||||||
|
|
|
Other control options (multiple selections possible) |
||||||||
|
|
|
room temperature control, with presence detection |
[yes/no] |
|
||||||
|
|
|
room temperature control, with open window detection |
[yes/no] |
|
||||||
|
Permanent pilot flame power requirement |
|
with distance control option |
[yes/no] |
|
||||||
|
Pilot flame power requirement (if applicable) |
Ppilot |
[x,xxx/N.A.] |
kW |
|
|
|||||
|
Contact details |
Name and address of the supplier |
|||||||||
ANNEX VI
Information to be provided in cases where end-users cannot be expected to see the product displayed, except on the internet
ANNEX VII
Information to be provided in the case of sale, hire or hire-purchase through the internet
ANNEX VIII
Measurements and calculations
|
If the product is equipped with (only one option may apply): |
F(2) |
|
Fuel fired local space heaters |
|
|
single stage heat output, no room temperature control |
0,0 % |
|
two or more manual stages, no temperature control |
1,0 % |
|
with mechanic thermostat room temperature control |
2,0 % |
|
with electronic room temperature control |
4,0 % |
|
with electronic room temperature control plus day timer |
6,0 % |
|
with electronic room temperature control plus week timer |
7,0 % |
|
If the product is equipped with (multiple options may apply): |
F(3) |
|
Fuel fired local space heaters |
|
|
room temperature control with presence detection |
1,0 % |
|
room temperature control with open window detection |
1,0 % |
|
with distance control option |
1,0 % |