COMMISSION DELEGATED REGULATION (EU) 2017/2293
of 3 August 2017
on the conditions for classification, without testing, of cross laminated timber products covered by the harmonised standard EN 16351 and laminated veneer lumber products covered by the harmonised standard EN 14374 with regard to their reaction to fire
(Text with EEA relevance)
Article 1
Article 2
ANNEX
Product(1) |
Product detail |
Minimum mean density(2) (kg/m3) |
Minimum overall thickness (mm) |
Class(3) |
Cross laminated timber products covered by the harmonised standard EN 16351 |
Minimum layer thickness of 18 mm |
350 |
54 |
D-s2, d0(4) |
Laminated veneer lumber products covered by the harmonised standard EN 14374 |
Minimum veneer thickness of 3 mm |
400 |
18 |
D-s2, d0(4) |
Product(5) |
Product detail |
Minimum mean density(6) (kg/m3) |
Minimum overall thickness (mm) |
Class for floorings(7) |
Cross laminated timber products covered by the harmonised standard EN 16351 |
minimum layer thickness of 18 mm and with the surface layer made of pine |
430 |
54 |
DFL-s1(8) |
Cross laminated timber products covered by the harmonised standard EN 16351 |
minimum layer thickness of 18 mm and with the surface layer made of spruce |
400 |
54 |
DFL-s1(8) |
Laminated veneer lumber products covered by the harmonised standard EN 14374 |
with a minimum veneer thickness of 3 mm and with the surface layer made of pine |
480 |
15 |
DFL-s1(8) |
Laminated veneer lumber products covered by the harmonised standard EN 14374 |
with a minimum veneer thickness of 3 mm and with the surface layer made of pine |
430 |
20 |
DFL-s1(8) |
Laminated veneer lumber products covered by the harmonised standard EN 14374 |
with a minimum veneer thickness of 3 mm and with the surface layer made of spruce |
400 |
15 |
DFL-s1(8) |