COMMISSION DELEGATED REGULATION (EU) 2019/1342
of 14 March 2019
supplementing Regulation (EU) No 305/2011 of the European Parliament and of the Council by establishing classes of performance in relation to air permeability for rooflights of plastics and glass and roof hatches
(Text with EEA relevance)
Article 1
Article 2
ANNEX
Classes of performance in relation to air permeability for roof lights of plastics and glass and roof hatches
Class |
Lower limit value of Internal Pressure (4 Pa) |
Higher limit value of Internal Pressure (100 Pa) |
||||||
Air permeability (in m3/(h.m)) |
||||||||
A (*1) |
< 1,4 |
< 12 |
||||||
B |
≥ 1,4 |
≥ 12 |
||||||
C |
≥ 6 |
≥ 50 |
||||||
Note: The boundaries of the classes used in this Table may be derived from the following formula: [Bild bitte in Originalquelle ansehen] Where:
|