COMMISSION REGULATION (EU) 2019/1781
of 1 October 2019
laying down ecodesign requirements for electric motors and variable speed drives pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Regulation (EC) No 641/2009 with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products and repealing Commission Regulation (EC) No 640/2009
(Text with EEA relevance)
Article 1
Subject matter
Article 2
Scope
Article 3
Definitions
Article 4
Ecodesign requirements
Article 5
Conformity assessment
Article 6
Verification procedure for market surveillance purposes
Article 7
Circumvention and software updates
Article 8
Benchmarks
Article 9
Review
Article 10
Repeal
Article 11
Amendment to Regulation (EC) No 641/2009
Article 12
Entry into force and application
ANNEX I
ECODESIGN REQUIREMENTS FOR MOTORS AND VARIABLE SPEED DRIVES
1. ENERGY EFFICIENCY REQUIREMENTS FOR MOTORS
Rated output power PN [kW] |
Number of poles |
|||
2 |
4 |
6 |
8 |
|
0,12 |
53,6 |
59,1 |
50,6 |
39,8 |
0,18 |
60,4 |
64,7 |
56,6 |
45,9 |
0,20 |
61,9 |
65,9 |
58,2 |
47,4 |
0,25 |
64,8 |
68,5 |
61,6 |
50,6 |
0,37 |
69,5 |
72,7 |
67,6 |
56,1 |
0,40 |
70,4 |
73,5 |
68,8 |
57,2 |
0,55 |
74,1 |
77,1 |
73,1 |
61,7 |
0,75 |
77,4 |
79,6 |
75,9 |
66,2 |
1,1 |
79,6 |
81,4 |
78,1 |
70,8 |
1,5 |
81,3 |
82,8 |
79,8 |
74,1 |
2,2 |
83,2 |
84,3 |
81,8 |
77,6 |
3 |
84,6 |
85,5 |
83,3 |
80,0 |
4 |
85,8 |
86,6 |
84,6 |
81,9 |
5,5 |
87,0 |
87,7 |
86,0 |
83,8 |
7,5 |
88,1 |
88,7 |
87,2 |
85,3 |
11 |
89,4 |
89,8 |
88,7 |
86,9 |
15 |
90,3 |
90,6 |
89,7 |
88,0 |
18,5 |
90,9 |
91,2 |
90,4 |
88,6 |
22 |
91,3 |
91,6 |
90,9 |
89,1 |
30 |
92,0 |
92,3 |
91,7 |
89,8 |
37 |
92,5 |
92,7 |
92,2 |
90,3 |
45 |
92,9 |
93,1 |
92,7 |
90,7 |
55 |
93,2 |
93,5 |
93,1 |
91,0 |
75 |
93,8 |
94,0 |
93,7 |
91,6 |
90 |
94,1 |
94,2 |
94,0 |
91,9 |
110 |
94,3 |
94,5 |
94,3 |
92,3 |
132 |
94,6 |
94,7 |
94,6 |
92,6 |
160 |
94,8 |
94,9 |
94,8 |
93,0 |
200 up to 1 000 |
95,0 |
95,1 |
95,0 |
93,5 |
Rated output power PN [kW] |
Number of poles |
|||
2 |
4 |
6 |
8 |
|
0,12 |
60,8 |
64,8 |
57,7 |
50,7 |
0,18 |
65,9 |
69,9 |
63,9 |
58,7 |
0,20 |
67,2 |
71,1 |
65,4 |
60,6 |
0,25 |
69,7 |
73,5 |
68,6 |
64,1 |
0,37 |
73,8 |
77,3 |
73,5 |
69,3 |
0,40 |
74,6 |
78,0 |
74,4 |
70,1 |
0,55 |
77,8 |
80,8 |
77,2 |
73,0 |
0,75 |
80,7 |
82,5 |
78,9 |
75,0 |
1,1 |
82,7 |
84,1 |
81,0 |
77,7 |
1,5 |
84,2 |
85,3 |
82,5 |
79,7 |
2,2 |
85,9 |
86,7 |
84,3 |
81,9 |
3 |
87,1 |
87,7 |
85,6 |
83,5 |
4 |
88,1 |
88,6 |
86,8 |
84,8 |
5,5 |
89,2 |
89,6 |
88,0 |
86,2 |
7,5 |
90,1 |
90,4 |
89,1 |
87,3 |
11 |
91,2 |
91,4 |
90,3 |
88,6 |
15 |
91,9 |
92,1 |
91,2 |
89,6 |
18,5 |
92,4 |
92,6 |
91,7 |
90,1 |
22 |
92,7 |
93,0 |
92,2 |
90,6 |
30 |
93,3 |
93,6 |
92,9 |
91,3 |
37 |
93,7 |
93,9 |
93,3 |
91,8 |
45 |
94,0 |
94,2 |
93,7 |
92,2 |
55 |
94,3 |
94,6 |
94,1 |
92,5 |
75 |
94,7 |
95,0 |
94,6 |
93,1 |
90 |
95,0 |
95,2 |
94,9 |
93,4 |
110 |
95,2 |
95,4 |
95,1 |
93,7 |
132 |
95,4 |
95,6 |
95,4 |
94,0 |
160 |
95,6 |
95,8 |
95,6 |
94,3 |
200 up to 1 000 |
95,8 |
96,0 |
95,8 |
94,6 |
Rated output power PN [kW] |
Number of poles |
|||
2 |
4 |
6 |
8 |
|
0,12 |
66,5 |
69,8 |
64,9 |
62,3 |
0,18 |
70,8 |
74,7 |
70,1 |
67,2 |
0,20 |
71,9 |
75,8 |
71,4 |
68,4 |
0,25 |
74,3 |
77,9 |
74,1 |
70,8 |
0,37 |
78,1 |
81,1 |
78,0 |
74,3 |
0,40 |
78,9 |
81,7 |
78,7 |
74,9 |
0,55 |
81,5 |
83,9 |
80,9 |
77,0 |
0,75 |
83,5 |
85,7 |
82,7 |
78,4 |
1,1 |
85,2 |
87,2 |
84,5 |
80,8 |
1,5 |
86,5 |
88,2 |
85,9 |
82,6 |
2,2 |
88,0 |
89,5 |
87,4 |
84,5 |
3 |
89,1 |
90,4 |
88,6 |
85,9 |
4 |
90,0 |
91,1 |
89,5 |
87,1 |
5,5 |
90,9 |
91,9 |
90,5 |
88,3 |
7,5 |
91,7 |
92,6 |
91,3 |
89,3 |
11 |
92,6 |
93,3 |
92,3 |
90,4 |
15 |
93,3 |
93,9 |
92,9 |
91,2 |
18,5 |
93,7 |
94,2 |
93,4 |
91,7 |
22 |
94,0 |
94,5 |
93,7 |
92,1 |
30 |
94,5 |
94,9 |
94,2 |
92,7 |
37 |
94,8 |
95,2 |
94,5 |
93,1 |
45 |
95,0 |
95,4 |
94,8 |
93,4 |
55 |
95,3 |
95,7 |
95,1 |
93,7 |
75 |
95,6 |
96,0 |
95,4 |
94,2 |
90 |
95,8 |
96,1 |
95,6 |
94,4 |
110 |
96,0 |
96,3 |
95,8 |
94,7 |
132 |
96,2 |
96,4 |
96,0 |
94,9 |
160 |
96,3 |
96,6 |
96,2 |
95,1 |
200 up to 249 |
96,5 |
96,7 |
96,3 |
95,4 |
250 up to 314 |
96,5 |
96,7 |
96,5 |
95,4 |
315 up to 1 000 |
96,5 |
96,7 |
96,6 |
95,4 |
IE code |
Coefficients |
2 poles |
4 poles |
6 poles |
8 poles |
IE2 |
A |
22,4864 |
17,2751 |
-15,9218 |
6,4855 |
B |
27,7603 |
23,978 |
-30,258 |
9,4748 |
|
C |
37,8091 |
35,5822 |
16,6861 |
36,852 |
|
D |
82,458 |
84,9935 |
79,1838 |
70,762 |
|
IE3 |
A |
6,8532 |
7,6356 |
-17,361 |
-0,5896 |
B |
6,2006 |
4,8236 |
-44,538 |
-25,526 |
|
C |
25,1317 |
21,0903 |
-3,0554 |
4,2884 |
|
D |
84,0392 |
86,0998 |
79,1318 |
75,831 |
|
IE4 |
A |
-8,8538 |
8,432 |
-13,0355 |
-4,9735 |
B |
-20,3352 |
2,6888 |
-36,9497 |
-21,453 |
|
C |
8,9002 |
14,6236 |
-4,3621 |
2,6653 |
|
D |
85,0641 |
87,6153 |
82,0009 |
79,055 |
IE code |
Coefficients |
2 poles |
4 poles |
6 poles |
8 poles |
IE2 |
A |
0,2972 |
0,0278 |
0,0148 |
2,1311 |
B |
-3,3454 |
-1,9247 |
-2,4978 |
-12,029 |
|
C |
13,0651 |
10,4395 |
13,247 |
26,719 |
|
D |
79,077 |
80,9761 |
77,5603 |
69,735 |
|
IE3 |
A |
0,3569 |
0,0773 |
0,1252 |
0,7189 |
B |
-3,3076 |
-1,8951 |
-2,613 |
-5,1678 |
|
C |
11,6108 |
9,2984 |
11,9963 |
15,705 |
|
D |
82,2503 |
83,7025 |
80,4769 |
77,074 |
|
IE4 |
A |
0,34 |
0,2412 |
0,3598 |
0,6556 |
B |
-3,0479 |
-2,3608 |
-3,2107 |
-4,7229 |
|
C |
10,293 |
8,446 |
10,7933 |
13,977 |
|
D |
84,8208 |
86,8321 |
84,107 |
80,247 |
2. PRODUCT INFORMATION REQUIREMENTS FOR MOTORS
3. EFFICIENCY REQUIREMENTS FOR VARIABLE SPEED DRIVES
Apparent output power of VSD (kVA) |
Rated power of Motor (kW) (indicative) |
Reference power losses (kW), at 90 % rated motor stator frequency and 100 % rated torque-producing current |
Test load displacement factor cos phi (+/- 0,08) |
0,278 |
0,12 |
0,100 |
0,73 |
0,381 |
0,18 |
0,104 |
0,73 |
0,500 |
0,25 |
0,109 |
0,73 |
0,697 |
0,37 |
0,117 |
0,73 |
0,977 |
0,55 |
0,129 |
0,73 |
1,29 |
0,75 |
0,142 |
0,79 |
1,71 |
1,1 |
0,163 |
0,79 |
2,29 |
1,5 |
0,188 |
0,79 |
3,3 |
2,2 |
0,237 |
0,79 |
4,44 |
3 |
0,299 |
0,79 |
5,85 |
4 |
0,374 |
0,79 |
7,94 |
5,5 |
0,477 |
0,85 |
9,95 |
7,5 |
0,581 |
0,85 |
14,4 |
11 |
0,781 |
0,85 |
19,5 |
15 |
1,01 |
0,85 |
23,9 |
18,5 |
1,21 |
0,85 |
28,3 |
22 |
1,41 |
0,85 |
38,2 |
30 |
1,86 |
0,85 |
47 |
37 |
2,25 |
0,85 |
56,9 |
45 |
2,70 |
0,86 |
68,4 |
55 |
3,24 |
0,86 |
92,8 |
75 |
4,35 |
0,86 |
111 |
90 |
5,17 |
0,86 |
135 |
110 |
5,55 |
0,86 |
162 |
132 |
6,65 |
0,86 |
196 |
160 |
8,02 |
0,86 |
245 |
200 |
10,0 |
0,87 |
302 |
250 |
12,4 |
0,87 |
381 |
315 |
15,6 |
0,87 |
429 |
355 |
17,5 |
0,87 |
483 |
400 |
19,8 |
0,87 |
604 |
500 |
24,7 |
0,87 |
677 |
560 |
27,6 |
0,87 |
761 |
630 |
31,1 |
0,87 |
858 |
710 |
35,0 |
0,87 |
967 |
800 |
39,4 |
0,87 |
1 088 |
900 |
44,3 |
0,87 |
1 209 |
1 000 |
49,3 |
0,87 |
4. PRODUCT INFORMATION REQUIREMENTS FOR VARIABLE SPEED DRIVES
ANNEX II
MEASUREMENT METHODS AND CALCULATIONS
1.
FOR MOTORS
2.
FOR VARIABLE SPEED DRIVES
ANNEX III
VERIFICATION PROCEDURE FOR MARKET SURVEILLANCE PURPOSES
Parameters |
Verification tolerances |
Total losses (1-η) for motors with a rated output equal to or above 0,12 kW and equal to or below 150 kW. |
The determined value (*1) shall not exceed the value (1-η) calculated based on the declared η by more than 15 %. |
Total losses (1-η) for motors with a rated output of above 150 kW and equal to or below 1 000 kW. |
The determined value (*1) shall not exceed the value (1-η) calculated based on the declared η by more than 10 %. |
Total losses for variable speed drives. |
The determined value (*1) shall not exceed the declared value by more than 10 %. |