COMMISSION REGULATION (EU) 2019/2023
of 1 October 2019
laying down ecodesign requirements for household washing machines and household washer-dryers pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EU) No 1015/2010
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements
Article 4
Conformity assessment
Article 5
Verification procedure for market surveillance purposes
Article 6
Circumvention
Article 7
Indicative benchmarks
Article 8
Review
Article 9
Amendment to Regulation (EC) No 1275/2008
Article 10
Repeal
Article 11
Transitional measures
Article 12
Entry into force and application
ANNEX I
Definitions applicable for the annexes
ANNEX II
Ecodesign requirements
1. PROGRAMME REQUIREMENTS
2. WASH AND DRY CYCLE
3. ENERGY EFFICIENCY REQUIREMENTS
4. FUNCTIONAL REQUIREMENTS
5. REQUIREMENTS ON DURATION
6. WEIGHTED WATER CONSUMPTION REQUIREMENT
7. LOW POWER MODES
8. RESOURCE EFFICIENCY REQUIREMENTS
9. INFORMATION REQUIREMENTS
ANNEX III
Measurement methods and calculations
1. ENERGY EFFICIENCY INDEX
1.1. Energy Efficiency Index (EEI
W
) of household washing machines and the washing cycle of household washer-dryers
1.2. Energy Efficiency Index (EEI
WD
) of the complete cycle of household washer-dryers
2. WASHING EFFICIENCY INDEX
3. RINSING EFFECTIVENESS
4. MAXIMUM TEMPERATURE
5. WEIGHTED WATER CONSUMPTION
6. REMAINING MOISTURE CONTENT
7. FINAL MOISTURE CONTENT
8. LOW POWER MODES
ANNEX IV
Verification procedure for market surveillance purposes
Parameter |
Verification tolerances |
EW,full, EW,½, EW,1/4, EWD,full, EWD,½ |
The determined value (*1) shall not exceed the declared value of EW,full, EW,½, EW,1/4, EWD,full and EWD,½, respectively, by more than 10 %. |
Weighted energy consumption (EW and EWD) |
The determined value (*1) shall not exceed the declared value of EW, respectively EWD, by more than 10 %. |
WW,full, WW,½ WW,1/4, WWD,full, WWD,½ |
The determined value (*1) shall not exceed the declared value of WW,full, WW,½, WW,1/4, WWD,full and WWD,½, respectively, by more than 10 %. |
Weighted water consumption (WW and WWD) |
The determined value (*1) shall not exceed the declared value of WW, respectively WWD, by more than 10 %. |
Washing efficiency index (IW and JW) |
The determined value (*1) shall not be less than the declared value of IW, respectively Jw, by more than 8 %. |
Rinsing effectiveness (IR and JR) |
The determined value (*1) shall not exceed the declared value of IR, respectively JR, by more than 1,0 g/kg. |
Duration of the eco 40-60 programme (tW) |
The determined value (*1) of the programme duration shall not exceed the declared value of tW by more than 5 % or by more than 10 minutes, whichever is the smaller. |
Duration of the wash and dry cycle (tWD) |
The determined value of the cycle duration shall not exceed the declared value of tWD by more than 5 % or by more than 10 minutes, whichever is the smaller. |
Maximum temperature inside the laundry (T) |
The determined value shall not be less than the declared values of T by more than 5 K and it shall not exceed the declared value of T by more than 5 K. |
Dfull, D½ D1/4 |
The determined value (*1) shall not exceed the declared value of Dfull, D½ and D1/4, respectively, by more than 10 %. |
Remaining moisture content after washing (D) |
The determined value (*1) shall not exceed the declared value of D by more than 10 %. |
Final moisture content after drying |
The determined value (*1) shall not exceed 3,0 %. |
Power consumption in off mode (Po) |
The determined value (*1) of power consumption Po shall not exceed the declared value by more than 0,10 W. |
Power consumption in standby mode (Psm) |
The determined value (*1) of power consumption Psm shall not exceed the declared value by more than 10 % if the declared value is higher than 1,00 W, or by more than 0,10 W if the declared value is lower than or equal to 1,00 W. |
Power consumption in delay start (Pds) |
The determined value (*1) of power consumption Pds shall not exceed the declared value by more than 10 % if the declared value is higher than 1,00 W, or by more than 0,10 W if the declared value is lower than or equal to 1,00 W. |