COMMISSION REGULATION (EU) 2019/2020
of 1 October 2019
laying down ecodesign requirements for light sources and separate control gears pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulations (EC) No 244/2009, (EC) No 245/2009 and (EU) No 1194/2012
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements
Article 4
Removal of light sources and separate control gears
Article 5
Conformity assessment
Article 6
Verification procedure for market surveillance purposes
Article 7
Circumvention
Article 8
Indicative benchmarks
Article 9
Review
Article 10
Repeal
Article 11
Entry into force and application
ANNEX I
Definitions applicable for the Annexes
ANNEX II
Ecodesign requirements
1. Energy efficiency requirements:
Light source description |
η |
L |
[lm/W] |
[W] |
|
LFL T5-HE |
98,8 |
1,9 |
LFL T5-HO, 4 000 ≤ Φ ≤ 5 000 lm |
83,0 |
1,9 |
LFL T5-HO, other lm output |
79,0 |
1,9 |
FL T5 circular |
79,0 |
1,9 |
FL T8 (including FL T8 U-shaped) |
89,7 |
4,5 |
From 1 September 2023, for FL T8 of 2-, 4- and 5-foot |
120,0 |
1,5 |
Magnetic induction light source, any length/flux |
70,2 |
2,3 |
CFLni |
70,2 |
2,3 |
FL T9 circular |
71,5 |
6,2 |
HPS single-ended |
88,0 |
50,0 |
HPS double-ended |
78,0 |
47,7 |
MH ≤ 405 W single-ended |
84,5 |
7,7 |
MH > 405 W single-ended |
79,3 |
12,3 |
MH ceramic double-ended |
84,5 |
7,7 |
MH quartz double-ended |
79,3 |
12,3 |
Organic light-emitting diode (OLED) |
65,0 |
1,5 |
Until 1 September 2023: HL G9, G4 and GY6.35 |
19,5 |
7,7 |
HL R7s ≤ 2 700 lm |
26,0 |
13,0 |
Other light sources in scope not mentioned above |
120,0 |
1,5 (*1) |
Light source type |
Basic C value |
Non-directional (NDLS) not operating on mains (NMLS) |
1,00 |
Non-directional (NDLS) operating on mains (MLS) |
1,08 |
Directional (DLS) not operating on mains (NMLS) |
1,15 |
Directional (DLS) operating on mains (MLS) |
1,23 |
Special light source feature |
Bonus on C |
FL or HID with CCT > 5 000 K |
+0,10 |
FL with CRI > 90 |
0,10 |
HID with second envelope |
+0,10 |
MH NDLS > 405 W with non-clear envelope |
+0,10 |
DLS with anti-glare shield |
+0,20 |
Colour-tuneable light source (CTLS) |
+0,10 |
High luminance light sources (HLLS) |
+0,0058 • Luminance-HLLS - 0,0167 |
Declared output power of the control gear (Pcg) or declared power of the light source (Pls) in W, as applicable |
Minimum energy efficiency |
Control gear for HL light sources |
|
all wattages Pcg |
0,91 |
Control gear for FL light sources |
|
Pls ≤ 5 |
0,71 |
5 < Pls ≤ 100 |
Pls/(2 × √(Pls/36) + 38/36 × Pls+1) |
100 < Pls |
0,91 |
Control gear for HID light sources |
|
Pls ≤ 30 |
0,78 |
30 < Pls ≤ 75 |
0,85 |
75 < Pls ≤ 105 |
0,87 |
105 < Pls ≤ 405 |
0,90 |
405 < Pls |
0,92 |
Control gear for LED or OLED light sources |
|
all wattages Pcg |
Pcg 0,81 /(1,09 × Pcg 0,81 + 2,10 ) |
2. Functional requirements
Colour rendering |
CRI ≥ 80 (except for HID with Φuse > 4 klm and for light sources intended for use in outdoor applications, industrial applications or other applications where lighting standards allow a CRI< 80, when a clear indication to this effect is shown on the light source packaging and in all relevant printed and electronic documentation) |
Displacement factor (DF, cos φ1) at power input Pon for LED and OLED MLS |
No limit at Pon ≤ 5 W, DF ≥ 0,5 at 5 W < Pon ≤ 10 W, DF ≥ 0,7 at 10 W < Pon ≤ 25 W DF ≥ 0,9 at 25 W < Pon |
Lumen maintenance factor (for LED and OLED) |
The lumen maintenance factor XLMF% after endurance testing according to Annex V shall be at least XLMF,MIN % calculated as follows: [Bild bitte in Originalquelle ansehen] where L70 is the declared L70B50 lifetime (in hours) If the calculated value for XLMF,MIN exceeds 96,0 %, an XLMF,MIN value of 96,0 % shall be used |
Survival factor (for LED and OLED) |
Light sources should be operational as specified in row ‘Survival factor (for LED and OLED)’ of Annex IV, Table 6, following the endurance testing given in Annex V. |
Colour consistency for LED and OLED light sources |
Variation of chromaticity coordinates within a six-step MacAdam ellipse or less. |
Flicker for LED and OLED MLS |
Pst LM ≤ 1,0 at full-load |
Stroboscopic effect for LED and OLED MLS |
SVM ≤ 0,4 at full-load (except for HID with Φuse > 4 klm and for light sources intended for use in outdoor applications, industrial applications or other applications where lighting standards allow a CRI< 80) |
3. Information requirements
ANNEX III
Exemptions
Blue |
440nm — 490nm |
90 % |
Green |
520nm — 570nm |
65 % |
Red |
610nm — 670nm |
95 % |
ANNEX IV
Verification procedure for market surveillance purposes
Parameter |
Sample size |
Verification tolerances |
Full-load on-mode power Pon [W]: |
|
|
Pon ≤ 2W |
10 |
The determined value shall not exceed the declared value by more than 0,20 W. |
2W < Pon ≤ 5W |
10 |
The determined value shall not exceed the declared value by more than 10 %. |
5W < Pon ≤ 25W |
10 |
The determined value shall not exceed the declared value by more than 5 %. |
25W < Pon ≤ 100W |
10 |
The determined value shall not exceed the declared value by more than 5 %. |
100W < Pon |
10 |
The determined value shall not exceed the declared value by more than 2,5 %. |
Displacement factor [0-1] |
10 |
The determined value shall not be less than the declared value minus 0,1 units. |
Useful luminous flux Φuse [lm] |
10 |
The determined value shall not be less than the declared value minus 10 %. |
No-load power Pno, Standby power Psb and Networked standby power Pnet [W] |
10 |
The determined value shall not exceed the declared value by more than 0,10 W. |
CRI [0-100] |
10 |
The determined value shall not be less than the declared value by more than 2,0 units. |
Flicker [Pst LM] and stroboscopic effect [SVM] |
10 |
The determined value shall not exceed the declared value by more than 10 %. |
Colour consistency [MacAdam ellips steps] |
10 |
The determined number of steps shall not exceed the declared number of steps. The centre of the MacAdam ellipse shall be the centre declared by the supplier with a tolerance of 0,005 units. |
Beam angle (degrees) |
10 |
The determined value shall not deviate from the declared value by more than 25 %. |
Control gear efficiency [0-1] |
3 |
The determined value shall not be less than the declared value minus 0,05 units. |
Lumen maintenance factor (for LED and OLED) |
10 |
The determined XLMF% of the sample following the test in Annex V of this Regulation shall not be less than XLMF, MIN%(1). |
Survival factor (for LED and OLED) |
10 |
At least 9 light sources of the test sample must be operational after completing the test in Annex V of this Regulation. |
Excitation purity [%] |
10 |
The determined value shall not be less than the declared value minus 5 %. |
Correlated colour temperature [K] |
10 |
The determined value shall not deviate from the declared value by more than 10 %. |