COMMISSION IMPLEMENTING DECISION (EU) 2021/1067
of 17 June 2021
on the harmonised use of radio spectrum in the 5 945-6 425 MHz frequency band for the implementation of wireless access systems including radio local area networks (WAS/RLANs)
(notified under document C(2021) 4240)
(Text with EEA relevance)
Article 1
Article 2
Article 3
Article 4
Article 5
ANNEX
Harmonised technical conditions for WAS/RLANs in the 5 945-6 425 MHz frequency band
Parameter |
Technical conditions |
||||
Permissible operation |
Restricted to indoor use, including in trains with metal-coated windows (note 1) and aircraft. Outdoor use, including in road vehicles, is not permitted. |
||||
Category of device |
An LPI access point or bridge that is supplied with power from a wired connection has an integrated antenna and is not battery powered. An LPI client device that is connected to an LPI access point or another LPI client device and may or may not be battery powered. |
||||
Frequency band |
5 945 -6 425 MHz |
||||
Maximum mean equivalent isotropically radiated power (‘e.i.r.p.’) for in-band emissions (note 2) |
23 dBm |
||||
Maximum mean e.i.r.p. density for in-band emissions (note 2) |
10 dBm/MHz |
||||
Maximum mean e.i.r.p. density for out-of-band emissions below 5 935 MHz (note 2) |
-22 dBm/MHz |
||||
|
Parameter |
Technical conditions |
||||||
Permissible operation |
Indoors and outdoors. Use on Unmanned Aircraft Systems (UAS) is not permitted. |
||||||
Category of device |
The VLP device is a portable device. |
||||||
Frequency band |
5 945 -6 425 MHz |
||||||
Maximum mean e.i.r.p. for in-band emissions (note 1) |
14 dBm |
||||||
Maximum mean e.i.r.p. density for in-band emissions (note 1) |
1 dBm/MHz |
||||||
Narrowband usage maximum mean e.i.r.p. density for in-band emissions (note 1) (note 2) |
10 dBm/MHz |
||||||
Maximum mean e.i.r.p. density for out-of-band emissions below 5 935 MHz (note 1) |
- 45 dBm/MHz until 31 December 2024 (note 3) |
||||||
|