COMMISSION REGULATION (EU) No 66/2014
of 14 January 2014
implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for domestic ovens, hobs and range hoods
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements and timetable
Article 4
Conformity assessment
Article 5
Verification procedure for market surveillance purposes
Article 6
Indicative benchmarks
Article 7
Review
Article 8
Entry into force and application
ANNEX I
Ecodesign requirements
1. ENERGY EFFICIENCY, AIR FLOW AND ILLUMINATION REQUIREMENTS
1.1.
For domestic ovens
|
Domestic electric & gas oven |
From 1 year after the entry into force |
EEIcavity < 146 |
From 2 years after the entry into force |
EEIcavity < 121 |
From 5 years after the entry into force |
EEIcavity < 96 |
1.2.
For domestic hobs
|
Electric hob (ECelectric hob in Wh/kg) |
Gas-fired hob (EEgas hob in %) |
From 1 year after the entry into force |
ECelectric hob < 210 |
EEgas hob > 53 |
From 3 years after the entry into force |
ECelectric hob < 200 |
EEgas hob > 54 |
From 5 years after the entry into force |
ECelectric hob < 195 |
EEgas hob > 55 |
1.3.
For domestic range hoods
1.3.1.
Energy Efficiency Index (EEI
hood
) and Fluid Dynamic Efficiency (FDE
hood
)
|
EEIhood |
FDEhood |
From 1 year after the entry into force |
EEIhood < 120 |
FDEhood > 3 |
From 3 years after the entry into force |
EEIhood < 110 |
FDEhood > 5 |
From 5 years after the entry into force |
EEIhood < 100 |
FDEhood > 8 |
1.3.2.
Air flow
1.3.3.
Low power modes for domestic range hoods
1.3.4.
Illumination of the lighting
2. PRODUCT INFORMATION REQUIREMENTS
2.1.
For domestic ovens
|
Symbol |
Value |
Unit |
Model identification |
|
|
|
Type of oven |
|
|
|
Mass of the appliance |
M |
X,X |
kg |
Number of cavities |
|
X |
|
Heat source per cavity (electricity or gas) |
|
|
|
Volume per cavity |
V |
X |
l |
Energy consumption (electricity) required to heat a standardised load in a cavity of an electric heated oven during a cycle in conventional mode per cavity (electric final energy) |
ECelectric cavity |
X,XX |
kWh/cycle |
Energy consumption required to heat a standardised load in a cavity of an electric heated oven during a cycle in fan-forced mode per cavity (electric final energy) |
ECelectric cavity |
X,XX |
kWh/cycle |
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in conventional mode per cavity (gas final energy) |
ECgas cavity |
X,XX X,XX |
MJ/cycle kWh/cycle(1) |
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in fan-forced mode per cavity (gas final energy) |
ECgas cavity |
X,XX X,XX |
MJ/cycle kWh/cycle |
Energy Efficiency Index per cavity |
EEIcavity |
X,X |
|
2.2.
For domestic hobs
2.2.1.
Domestic electric hobs
|
Symbol |
Value |
Unit |
Model identification |
|
|
|
Type of hob |
|
|
|
Number of cooking zones and/or areas |
|
X |
|
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) |
|
|
|
For circular cooking zones or area: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm |
Ø |
X,X |
cm |
For non-circular cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm |
L W |
X,X X,X |
cm |
Energy consumption per cooking zone or area calculated per kg |
ECelectric cooking |
X,X |
Wh/kg |
Energy consumption for the hob calculated per kg |
ECelectric hob |
X,X |
Wh/kg |
2.2.2.
Domestic gas-fired hobs
|
Symbol |
Value |
Unit |
Model identification |
|
|
|
Type of hob |
|
|
|
Number of gas burners |
|
X |
|
Energy efficiency per gas burner |
EEgas burner |
X,X |
|
Energy efficiency for the gas hob |
EEgas hob |
X,X |
|
2.2.3.
Domestic mixed gas and electric hobs
|
Symbol |
Value |
Unit |
Model identification |
|
|
|
Type of hob |
|
|
|
Number of electric cooking zones and/or areas |
|
X |
|
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) per electric cooking zone and/or area |
|
|
|
For circular electric cooking zones: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm |
Ø |
X,X |
cm |
For non-circular electric cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm |
L W |
X,X X,X |
cm |
Energy consumption per electric cooking zone or area calculated per kg |
ECelectric cooking |
X |
Wh/kg |
Number of gas fired burners |
|
X |
|
Energy efficiency per gas burner |
EEgas burner |
X,X |
|
2.3.
For domestic range hoods
|
Symbol |
Value |
Unit |
Model identification |
|
|
|
Annual Energy Consumption |
AEChood |
X,X |
kWh/a |
Time increase factor |
f |
X,X |
|
Fluid Dynamic Efficiency |
FDEhood |
X,X |
|
Energy Efficiency Index |
EEIhood |
X,X |
|
Measured air flow rate at best efficiency point |
QBEP |
X,X |
m3/h |
Measured air pressure at best efficiency point |
PBEP |
X |
Pa |
Maximum air flow |
Qmax |
X,X |
m3/h |
Measured electric power input at best efficiency point |
WBEP |
X,X |
W |
Nominal power of the lighting system |
WL |
X,X |
W |
Average illumination of the lighting system on the cooking surface |
Emiddle |
X |
lux |
Measured power consumption in standby mode |
Ps |
X,XX |
W |
Measured power consumption off mode |
Po |
X,XX |
W |
Sound power level |
LWA |
X |
dB |
ANNEX II
Measurements and calculations
1. DOMESTIC OVENS
2. DOMESTIC HOBS
2.1.
Domestic electric hobs
2.2.
Domestic gas hobs
2.3.
Domestic mixed electric/gas hobs
3. DOMESTIC RANGE HOODS
3.1.
Calculation of the Energy Efficiency Index (EEI
hood
)
3.2.
Calculation of the Fluid Dynamic Efficiency (FDE
hood
)
3.3.
Calculation on the limitation of the exhaust air
3.4.
Illumination of lighting system (E
middle
)
3.5.
Noise
ANNEX III
Procedure for product conformity checking by market surveillance authorities
Measured parameters |
Verification tolerances |
Mass of the domestic oven (M) |
The determined value shall not exceed the declared value of M by more than 5 %. |
Volume of the cavity of the domestic oven (V) |
The determined value shall not be lower than the declared value of V by more than 5 %. |
ECelectric cavity, ECgas cavity |
The determined value shall not exceed the declared value of ECelectric cavity, ECgas cavity by more than 5 %. |
ECelectric hob |
The determined value shall not exceed the declared value of ECelectric hob by more than 5 %. |
EEgas hob |
The determined value shall not be lower than the declared value of EEgas hob by more than 5 %. |
WBEP, WL |
The determined value shall not exceed the declared value of WBEP, WL by more than 5 %. |
QBEP, PBEP |
The determined value shall not be lower than the declared value of QBEP, PBEP by more than 5 %. |
Qmax |
The determined value shall not exceed the declared value of Qmax by more than 8 %. |
Emiddle |
The determined value shall not be lower than the declared value of Emiddle by more than 5 %. |
Sound power level LWA |
The determined value shall not exceed the declared value. |
Po, Ps |
The determined value of power consumption Po and Ps shall not exceed the declared value by more than 10 %. The determined value of power consumption Po and Ps of less than or equal to 1,00 W shall not exceed the declared value by more than 0,10 W. |
ANNEX IV
Indicative benchmarks
Domestic ovens |
Electric |
EEIcavity = 70,7 |
Gas |
EEIcavity = 75,4 |
|
Domestic hobs |
Electric |
ECelectric cooking = 169,3 |
Gas |
EEgas burner = 63,5 % |
|
Domestic range hoods |
Air flow |
FDEhood = 22 |
Noise |
51 dB at 550 m3/h; 57 dB at 750 m3/h |