COMMISSION REGULATION (EU) 2015/1188
of 28 April 2015
implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements and timetable
Article 4
Conformity assessment
Article 5
Verification procedure for market surveillance purposes
Article 6
Indicative benchmarks
Article 7
Review
Article 8
Transitional provisions
Article 9
Entry into force
ANNEX I
Definitions applicable for Annexes II to V
ANNEX II
Ecodesign requirements
1.
Specific ecodesign requirements for seasonal space heating energy efficiency
2.
Specific ecodesign requirements for emissions
3.
Requirements for product information
Model identifier(s): |
|||||||||||
Indirect heating functionality: [yes/no] |
|||||||||||
Direct heat output: …(kW) |
|||||||||||
Indirect heat output: …(kW) |
|||||||||||
Fuel |
|
|
Space heating emissions(1) |
||||||||
NOx |
|||||||||||
Select fuel type |
[gaseous/liquid] |
[specify] |
[mg/kWhinput] (GCV) |
||||||||
|
|
|
|
||||||||
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
|||
Heat output |
|
Useful efficiency (NCV) |
|||||||||
Nominal heat output |
Pnom |
x,x |
kW |
|
Useful efficiency at nominal heat output |
ηth,nom |
x,x |
% |
|||
Minimum heat output (indicative) |
Pmin |
[x,x/N.A.] |
kW |
|
Useful efficiency at minimum heat output (indicative) |
ηth,min |
[x,x/N.A.] |
% |
|||
|
|
|
|
|
|
||||||
Auxiliary electricity consumption |
|
Type of heat output/room temperature control (select one) |
|||||||||
At nominal heat output |
elmax |
x,xxx |
kW |
|
single stage heat output, no room temperature control |
[yes/no] |
|||||
At minimum heat output |
elmin |
x,xxx |
kW |
|
two or more manual stages, no room temperature control |
[yes/no] |
|||||
In standby mode |
elSB |
x,xxx |
kW |
|
with mechanic thermostat room temperature control |
[yes/no] |
|||||
|
|
with electronic room temperature control |
[yes/no] |
||||||||
|
|
with electronic room temperature control plus day timer |
[yes/no] |
||||||||
|
|
with electronic room temperature control plus week timer |
[yes/no] |
||||||||
|
|
Other control options (multiple selections possible) |
|||||||||
|
|
room temperature control, with presence detection |
[yes/no] |
||||||||
|
|
room temperature control, with open window detection |
[yes/no] |
||||||||
|
|
with distance control option |
[yes/no] |
||||||||
|
|
with adaptive start control |
[yes/no] |
||||||||
|
|
with working time limitation |
[yes/no] |
||||||||
|
|
with black bulb sensor |
[yes/no] |
||||||||
Permanent pilot flame power requirement |
|
|
|||||||||
Pilot flame power requirement (if applicable) |
Ppilot |
[x,xxx/N.A.] |
kW |
|
|
||||||
Contact details |
Name and address of the manufacturer or its authorised representative. |
Model identifier(s): |
||||||
Item |
Symbol |
Value |
Unit |
|
Item |
Unit |
Heat output |
|
Type of heat input, for electric storage local space heaters only (select one) |
||||
Nominal heat output |
Pnom |
x,x |
kW |
|
manual heat charge control, with integrated thermostat |
[yes/no] |
Minimum heat output (indicative) |
Pmin |
[x,x/N.A.] |
kW |
|
manual heat charge control with room and/or outdoor temperature feedback |
[yes/no] |
Maximum continuous heat output |
Pmax,c |
x,x |
kW |
|
electronic heat charge control with room and/or outdoor temperature feedback |
[yes/no] |
Auxiliary electricity consumption |
|
|
|
|
fan assisted heat output |
[yes/no] |
At nominal heat output |
elmax |
x,xxx |
kW |
|
Type of heat output/room temperature control (select one) |
|
At minimum heat output |
elmin |
x,xxx |
kW |
|
single stage heat output and no room temperature control |
[yes/no] |
In standby mode |
elSB |
x,xxx |
kW |
|
Two or more manual stages, no room temperature control |
[yes/no] |
|
|
with mechanic thermostat room temperature control |
[yes/no] |
|||
|
|
with electronic room temperature control |
[yes/no] |
|||
|
|
electronic room temperature control plus day timer |
[yes/no] |
|||
|
|
electronic room temperature control plus week timer |
[yes/no] |
|||
|
|
Other control options (multiple selections possible) |
||||
|
|
room temperature control, with presence detection |
[yes/no] |
|||
|
|
room temperature control, with open window detection |
[yes/no] |
|||
|
|
with distance control option |
[yes/no] |
|||
|
|
with adaptive start control |
[yes/no] |
|||
|
|
with working time limitation |
[yes/no] |
|||
|
|
with black bulb sensor |
[yes/no] |
|||
Contact details |
Name and address of the manufacturer or its authorised representative. |
Model identifier(s): |
|||||||||||||
Type of heating:[luminous/radiant tube] |
|||||||||||||
Fuel |
Fuel |
|
|
Space heating emissions(2) |
|||||||||
NOx |
|||||||||||||
Select fuel type |
[gaseous/liquid] |
[specify] |
|
mg/kWhinput (GCV) |
|||||||||
|
|
|
|
|
|||||||||
Characteristics when operating with the preferred fuel only |
|||||||||||||
Item |
Symbol |
Value |
Unit |
|
Item |
Symbol |
Value |
Unit |
|||||
Heat output |
|
Useful efficiency (GCV) — tube local space heaters only (3) |
|||||||||||
Nominal heat output |
Pnom |
x,x |
kW |
|
Useful efficiency at nominal heat output |
ηth,nom |
x,x |
% |
|||||
Minimum heat output |
Pmin |
[x,x/N.A.] |
kW |
|
Useful efficiency at minimum heat output |
ηth,min |
[x,x/N.A.] |
% |
|||||
Minimum heat output (as percentage of nominal heat output) |
.. |
[x] |
% |
|
|
|
|
|
|||||
Nominal tube system heat output (if applicable) |
Psystem |
x,x |
kW |
|
|
|
|
|
|||||
Nominal tube segment heat output (if applicable) |
Pheater,i |
[x,x/N.A.] |
kW |
|
Useful efficiency of tube segment at minimum heat output (if applicable) |
ηi |
[x,x/N.A.] |
% |
|||||
(repeat for multiple segments, if applicable) |
.. |
[x,x/N.A.] |
kW |
|
(repeat for multiple segments, if applicable) |
.. |
[x,x/N.A.] |
% |
|||||
number of identical tube segments |
n |
[x] |
[-] |
|
|
|
|
|
|||||
Radiant factor |
|
|
|
|
Envelope losses |
|
|
|
|||||
radiant factor at nominal heat output |
RFnom |
[x,x] |
[-] |
|
Envelope insulation class |
U |
|
W/(m2K) |
|||||
radiant factor at minimum heat output |
RFmin |
[x,x] |
[-] |
|
Envelope loss factor |
Fenv |
[x,x] |
% |
|||||
radiant factor of tube segment at nominal heat output |
RFi |
[x,x] |
[-] |
|
Heat generator to be installed outside the heated area |
|
[yes/no] |
|
|||||
(repeat for multiple segments, if applicable) |
.. |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|||||
Auxiliary electricity consumption |
|
Heat output control type (select one) |
|||||||||||
At nominal heat output |
elmax |
x,xxx |
kW |
|
|
[yes/no] |
|
||||||
At minimum heat output |
elmin |
x,xxx |
kW |
|
|
[yes/no] |
|
||||||
In standby mode |
elSB |
x,xxx |
kW |
|
|
[yes/no] |
|
||||||
|
|
|
|||||||||||
Permanent pilot flame power requirement |
|
|
|||||||||||
Pilot flame power requirement (if applicable) |
Ppilot |
[x,xxx/N.A.] |
kW |
|
|
||||||||
Contact details |
Name and address of the manufacturer or its authorised representative. |
ANNEX III
Measurements and calculations
2.
General conditions for measurements and calculations
3.
General conditions for seasonal space heating energy efficiency
4.
General conditions for emissions
5.
Specific conditions for seasonal space heating energy efficiency
Thermal transmittance of envelope (U) |
|
U ≤ 0,5 |
2,2 % |
0,5 < U ≤ 1,0 |
2,4 % |
1,0 < U ≤ 1,4 |
3,2 % |
1,4 < U ≤ 2,0 |
3,6 % |
U > 2,0 |
6,0 % |
If the product is equipped with (only one option may apply): |
F(1) is increased by |
Manual heat charge control, with integrated thermostat |
0,0 % |
Manual heat charge control with room and/or outdoor temperature feedback |
2,0 % |
Electronic heat charge control with room and/or outdoor temperature feedback or controlled by energy supplier |
3,5 % |
If the heat output control type of the products is: |
F(1) is calculated as: |
Single stage |
F(1) = 5 % |
Two stage |
[Bild bitte in Originalquelle ansehen] |
Modulating |
[Bild bitte in Originalquelle ansehen] |
If the product is equipped with (only one option may apply): |
F(2) |
|||||
for electric local space heaters |
for local space heaters using gaseous or liquid fuels |
|||||
Portable |
Fixed |
Storage |
Underfloor |
Radiant |
||
Single stage heat output, no room temperature control |
0,0 % |
0,0 % |
0,0 % |
0,0 % |
0,0 % |
0,0 % |
Two or more manual stages, no temperature control |
1,0 % |
0,0 % |
0,0 % |
0,0 % |
2,0 % |
1,0 % |
With mechanic thermostat room temperature control |
6,0 % |
1,0 % |
0,5 % |
1,0 % |
1,0 % |
2,0 % |
With electronic room temperature control |
7,0 % |
3,0 % |
1,5 % |
3,0 % |
2,0 % |
4,0 % |
With electronic room temperature control plus day timer |
8,0 % |
5,0 % |
2,5 % |
5,0 % |
3,0 % |
6,0 % |
With electronic room temperature control plus week timer |
9,0 % |
7,0 % |
3,5 % |
7,0 % |
4,0 % |
7,0 % |
If the product is equipped with (multiple options may apply): |
F(3) |
|||||
for electric local space heaters |
for local space heaters using gaseous or liquid fuels |
|||||
Portable |
Fixed |
Storage |
Underfloor |
Radiant |
||
Room temperature control with presence detection |
1,0 % |
0,0 % |
0,0 % |
0,0 % |
2,0 % |
1,0 % |
Room temperature control with open window detection |
0,0 % |
1,0 % |
0,5 % |
1,0 % |
1,0 % |
1,0 % |
With distance control option |
0,0 % |
1,0 % |
0,5 % |
1,0 % |
1,0 % |
1,0 % |
With adaptive start control |
0,0 % |
1,0 % |
0,5 % |
1,0 % |
0,0 % |
0,0 % |
With working time limitation |
0,0 % |
0,0 % |
0,0 % |
0,0 % |
1,0 % |
0,0 % |
With black bulb sensor |
0,0 % |
0,0 % |
0,0 % |
0,0 % |
1,0 % |
0,0 % |