determining the Community position for a decision of the Management entities under the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment on the revision of the computer specifications in Annex C, part VIII, to the Agreement
(Text with EEA relevance)
(2009/489/EC)
Sole Article
ANNEX
DRAFT DECISION
of […]
of the Management entities under the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment on the revision of the computer specifications in Annex C, part VIII, to the Agreement
ANNEX
ANNEX C, part VIII, TO THE AGREEMENT
VIII. COMPUTER SPECIFICATIONS
1.
DEFINITIONS
Components
Computer Types
Operational Modes
Networking and Power Management
Marketing and Shipment Channels
2.
QUALIFYING PRODUCTS
Products Covered by this Version 5,0 Specification |
Products Not Covered by this Version 5,0 Specification |
||||||||||||||||
|
|
3.
ENERGY-EFFICIENCY AND POWER MANAGEMENT CRITERIA
A.
Power supply efficiency requirements
B.
Efficiency and performance requirements
1.
Desktop, Integrated Desktop, and Notebook Levels
Desktop Categories for TEC Criteria
Notebook Categories for TEC Criteria
TEC (Desktop and Notebook product categories)
|
Desktops and Integrated Computers (kWh) |
Notebook Computers (kWh) |
TEC |
Category A: ≤ 148,0 Category B: ≤ 175,0 Category C: ≤ 209,0 Category D: ≤ 234,0 |
Category A: ≤ 40,0 Category B: ≤ 53,0 Category C: ≤ 88,5 |
Capability Adjustments |
||
Memory |
1 kWh (per GB over base) Base Memory: Categories A, B and C: 2 GB Category D: 4 GB |
0,4 kWh (per GB over 4) |
Premium Graphics (for Discrete GPUs with specified Frame Buffer Widths) |
Categories A and B: 35 kWh (FB Width ≤ 128-bit) 50 kWh (FB Width > 128-bit) Categories C and D: 50 kWh (FB Width > 128-bit) |
Category B: 3 kWh (FB Width > 64-bit) |
Additional Internal Storage |
25 kWh |
3 kWh |
(in %) |
||||
|
Desktop |
Notebook |
||
|
Conventional |
Proxying(1) |
Conventional |
Proxying(1) |
Toff |
55 |
40 |
60 |
45 |
Tsleep |
5 |
30 |
10 |
30 |
Tidle |
40 |
30 |
30 |
25 |
2.
Workstation Levels
P
TEC
(Workstation product category)
Table 3
P
TEC
Requirement — Workstations
(in %) |
|
Toff |
35 |
Tsleep |
10 |
Tidle |
55 |
Note: Weightings are included in the PTEC formula, above. |
Multiple Graphics Devices (Workstations)
3.
Small-Scale Server Levels
Small-Scale Server Operational Mode Power Requirements |
|
Off Mode: ≤ 2,0 W Idle State: Category A: ≤ 50,0 W Category B: ≤ 65,0 W |
|
Capability |
Additional Power Allowance |
Wake On LAN (WOL) (Applies only if computer is shipped with WOL enabled) |
+ 0,7 W for Off |
4.
Thin Client Levels
Thin Client Operational Mode Power Requirements |
|
Off Mode: ≤ 2 W Sleep Mode (if applicable): ≤ 2 W Idle State: Category A: ≤ 12,0 W Category B: ≤ 15,0 W |
|
Capability |
Additional Power Allowance |
Wake On LAN (WOL) (Applies only if computer is shipped with WOL enabled) |
+ 0,7 W for Sleep + 0,7 W for Off |
C.
Power Management Requirements
Specification Requirement |
|
Applicable to |
||||
Shipment Requirements |
||||||
Sleep Mode |
Shipped with a Sleep mode which is set to activate within 30 minutes of user inactivity. Computers shall reduce the speed of any active 1 Gb/s Ethernet network links when transitioning to Sleep or Off. |
Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||
Integrated Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Notebook Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Workstations |
[Bild bitte in Originalquelle ansehen] |
|||||
|
|
|||||
Small-Scale Servers |
[Bild bitte in Originalquelle ansehen] |
|||||
Thin Clients |
|
|||||
Display Sleep Mode |
Shipped with the display’s Sleep mode set to activate within 15 minutes of user inactivity. |
Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||
Integrated Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Notebook Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Workstations |
[Bild bitte in Originalquelle ansehen] |
|||||
|
|
|||||
Small-Scale Servers (if computer display is present) |
[Bild bitte in Originalquelle ansehen] |
|||||
Thin Clients |
[Bild bitte in Originalquelle ansehen] |
|||||
Network Requirements for Power Management |
||||||
Wake on LAN (WOL) |
Computers with Ethernet capability shall have the ability to enable and disable WOL for Sleep mode. |
Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||
Integrated Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Notebook Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Workstations |
[Bild bitte in Originalquelle ansehen] |
|||||
|
|
|||||
Small-Scale Servers |
[Bild bitte in Originalquelle ansehen] |
|||||
Thin Clients (Only applies if software updates from the centrally managed network are conducted while the unit is in sleep or off mode. Thin Clients whose standard framework for upgrading client software does not require off-hours scheduling are exempt from the requirement.) |
[Bild bitte in Originalquelle ansehen] |
|||||
Applies to computers shipped through Enterprise Channels, only: Computers with Ethernet capability must meet one of the following requirements:
|
Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
||||
Integrated Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Notebook Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Workstations |
[Bild bitte in Originalquelle ansehen] |
|||||
|
|
|||||
Small-Scale Servers |
[Bild bitte in Originalquelle ansehen] |
|||||
Thin Clients (Only applies if software updates from the centrally managed network are conducted while the unit is in sleep or off mode. Thin Clients whose standard framework for upgrading client software does not require off-hours scheduling are exempt from the requirement.) |
[Bild bitte in Originalquelle ansehen] |
|||||
|
||||||
Wake Management |
Applies to computers shipped through Enterprise Channels, only: Computers with Ethernet capability shall be capable of both remote (via network) and scheduled wake events from Sleep mode (e.g. Real Time Clock). Manufacturers shall ensure, where the manufacturer has control (i.e. configured through hardware settings rather than software settings), that these settings can be managed centrally, as the client wishes, with tools provided by the manufacturer. |
Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||
Integrated Desktop Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Notebook Computers |
[Bild bitte in Originalquelle ansehen] |
|||||
Workstations |
[Bild bitte in Originalquelle ansehen] |
|||||
|
|
|||||
Small-Scale Servers |
[Bild bitte in Originalquelle ansehen] |
|||||
Thin Clients |
[Bild bitte in Originalquelle ansehen] |
|||||
|
Qualifying Computers with Power Management Capabilities
Customer software and management service pre-Provisioning
User Information Requirement
D.
Voluntary Requirements
User Interface
4.
TEST PROCEDURES
1.
Number of Units Required for TEC or Idle Testing
2.
Models Capable of Operating at Multiple Voltage/Frequency Combinations
Product Category |
Specification Requirement |
Test Protocol |
Source |
All Computers |
Power Supply Efficiency |
IPS: Generalised Internal Power Supply Efficiency Test Protocol Rev. 6.4.2 EPS: ENERGY STAR Test Method for External Power Supplies Note: Should any information/procedures in addition to those described by the Internal Power Supply Efficiency Protocol be required in order to test an Internal Power Supply, partners must make available to EPA or the European Commission, as appropriate, upon request, the test setup used to acquire IPS data used in a product submittal. |
IPS: www.efficientpowersupplies.org EPS: www.energystar.gov/powersupplies |
Desktop, Integrated, and Notebook Computers |
ETEC (from measurements of Off Mode, Sleep Mode, and Idle State) |
ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III |
Appendix A |
Workstations |
PTEC (from measurements of Off Mode, Sleep Mode, Idle State, and Maximum Power) |
ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III-IV |
|
Small-Scale Servers |
Off Mode and Idle State |
ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III |
|
Thin Clients |
Off Mode, Sleep Mode, and Idle State |
ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III |
3.
Qualifying Families of Products
5.
EFFECTIVE DATE
Desktop, Integrated Desktop, Notebook, Workstation, Small-Scale Server
6.
FUTURE SPECIFICATION REVISIONS
Appendix A
ENERGY STAR Test Procedure for Determining the Power Use of Computers in Off, Sleep, and Idle
I.
Definitions
II.
Testing Requirements
1.
Approved Meter:
2.
Accuracy
3.
Test Conditions
Supply Voltage |
North America/Taiwan: |
115 (± 1 %) Volts AC, 60 Hz (± 1 %) |
Europe/Australia/New Zealand: |
230 (± 1 %) Volts AC, 50 Hz (± 1 %) |
|
Japan: |
100 (± 1 %) Volts AC, 50 Hz (± 1 %)/60 Hz (± 1 %) Note: For products rated for > 1,5 kW maximum power, the voltage range is ± 4 % |
|
Total Harmonic Distortion (THD) (Voltage) |
< 2 % THD (< 5 % for products which are rated for > 1,5 kW maximum power) |
|
Ambient Temperature |
23 °C ± 5 °C |
|
Relative Humidity |
10-80 % |
|
(Reference IEC 62301: Household Electrical Appliances — Measurement of Standby Power, Sections 4.2, 4.3, 4.4). |
4.
Test Configuration
III.
Test Procedure for Off, Sleep and Idle for All Computer Products
UUT Preparation
Off Mode Testing
Idle Mode Testing
Sleep Mode Testing
Reporting Test Results
IV.
Maximum Power Test for Workstations
Linpack |
http://www.netlib.org/linpack/ |
SPECviewperf® |
http://www.spec.org/benchmarks.html#gpc |
UUT Preparation
Maximum Power Testing
Reporting Test Results
V.
Continuing Verification
Appendix B
Sample Calculations
(in %) |
|
Toff |
60 |
Tsleep |
10 |
Tidle |
30 |
(in kWh) |
|
Notebook Computers |
|
Category A |
40 |
Category B |
53 |
Category C |
88,5 |
(in %) |
|
Toff |
35 |
Tsleep |
10 |
Tidle |
55 |